Technical specificaiton for Power plant equipments | |||
Ⅰ. Gen-set technical specification | |||
No. | Item | Unit | Specification |
1 | Model | 1250/2000/2500/3500GF | |
2 | Rated power | kW | 1250/2000/2500/3500 |
3 | Rated rev. | rpm | 600 |
4 | Rated voltage | V | 11000 |
5 | Rated current | A | 229.6 |
6 | Frequency | Hz | 50Hz |
7 | Power factor | 0.8 (lagging) | |
8 | Phase | 3-phase | |
9 | Voltage fluctuation rate | % | ±1 |
10 | Frequency (rev.) fluctuation rate | % | ±0.5 |
11 | Stable voltage regulating rate | % | ±2.5 |
12 | Stable frequency (rev.) regulating rate | % | 5 |
13 | Transient voltage regulating rate | % | ±20~-15 |
14 | Stabilizing time | s | 5 |
15 | Voltage regulating method | Auto | |
16 | Speed Governor | Electronic hydraulic | |
17 | Frequency regulating method | Auto/Manual | |
18 | Lubricating method | Pressure lubricating | |
19 | Cooling method | Close circuit of fresh cooling water | |
20 | Coupling | Flexiable | |
21 | Painting color | Blue | |
22 | Overall dimension | mm | 9890x2560x4015 |
23 | Net weight | kg | 75000 |
Ⅱ. Diesel engine specification | |||
No. | Item | Unit | Specification |
1 | Engine Model | DN8340ZD2 | |
2 | Type | In-line, 8-Cyls, four-stroke, direct injection, charged, inter cooled | |
3 | Bore | mm | 340 |
4 | Stroke | mm | 450 |
5 | Total displacemen | L | 408.35 |
6 | Mean piston seed | m/s | 9 |
7 | Rated power | KW | 4200 |
8 | Rated rev. | rpm | 600 |
9 | Overload (1 hr per 12 hrs) | kW/rpm | 4620/600 |
10 | Mean effective pressure | MPa | 2.56 |
11 | Compression ratio | 13.5 | |
12 | Rotation direction | Clockwise, viewed from flywheel end. | |
13 | Firing order | 1-4-7-6-8-5-2-3 | |
14 | Specific fuel oil consumption | g/kW.h | 198+3% |
15 | Specific Lube oil consumption | g/kW.h | < 1.2g/kW.h |
16 | Smoke | RB | ≤0.3 |
17 | Noise | dB(A) | 105 |
18 | Starting method | Air Rotary valve | |
19 | Cooling system | Fresh water cooling | |
20 | Lubricating system | Pressure lubricating | |
21 | Fuel oil specification | Diesel oil and 720Cst/50℃ HFO | |
22 | Lube oil specification | CD40 with TBN according HFO | |
23 | Piston lifting height | mm | 2365 |
24 | Overall dimension | mm | 7213×1850×3625mm |
25 | Net weight | kg | 47000 |
Ⅲ. Alternator specification | |||
No. | Item | Unit | Specification |
1 | Alternator Model | TFW3800 | |
2 | Type | Brushless generator | |
3 | Rated power | kW | 3500 |
4 | Rated voltage | V | 11000 |
5 | Rated current | A | 229.6 |
6 | Frequency | Hz | 50 |
7 | Power factor | 0.8 (lagging) | |
8 | Working condition | Continuous | |
9 | Phase and connection | 3-phase | |
10 | Voltage regulation method | Brushless, self excited | |
11 | Insulation Class | F | |
12 | Protection Class | IP23 | |
Ⅳ Cooling tower specification | |||
No. | Item | Unit | Specification |
1 | Cooling tower model | GBL-150 | |
2 | Inlet temperature | ℃ | 60 |
3 | Outlet | ℃ | 35 |
4 | Base Plane Size | mm | Ф4460×5095 |
5 | Blade amount | 4 | |
6 | Fan diameter | mm | Ф3400 |
7 | Motor fan power | kW | 11 |
8 | Inlet pipe demension | mm | DN200 |
9 | Outlet pipe demension | mm | DN250 |
G300 Statinary Generating Sets Main Specification | ||||||||
Model | 1000GF1 | 1250GF3 | 1350GF4 | 1400GF4 | ||||
Rated power, KW | 1000 | 1250 | 1350 | 1400 | ||||
Overload , KW | 1100 | 1375 | 1485 | 1540 | ||||
Rated voltage, V | 400/415/440/3300/6300/10500/13800 | |||||||
Rated current , A | ||||||||
Frequency , Hz | 50 | 60 | 50 | 60 | 50 | 60 | 50 | 60 |
Power factor | 0.8 Lagging | |||||||
Phase | 3 | |||||||
Diesel engine | G6300ZD6 | G6300ZD8 | G8300ZD6 | G6300ZD10 | G8300ZD10 | G8300ZD8 | G8300ZD10 | G8300ZD8 |
Rated power, KW | 1103 | 1470 | 1471 | 1471 | 1765 | 2000 | 1765 | 2000 |
Rated rev, rpm | 500 | 600 | 500 | 600 | 500 | 600 | 500 | 600 |
Alternator | 3 phase alternator | |||||||
voltage fluctuation rate% | <0.5 | <0.5 | ||||||
Frequency fluctuation rate, % | <0.5 | <0.5 | ||||||
Stable voltage regulating rate, % | ±1.0 | ±1.0 | ||||||
Transient voltage regulating rate, % | +20, -15 | +20, -15 | ||||||
Stable Frequency fluctuation rate, % | <3 | <0.5 | ||||||
Transient frequency regulating rate, % | +12, -10 | |||||||
Stablizing time, voltage , S | <4 | |||||||
Stablizing time, frequency , S | <3 | |||||||
voltage regulating method | automatic and munual | |||||||
Frequency regulating method | manual | |||||||
starting method | compressed air | |||||||
Lubricating method | pressue lubricating | |||||||
Cooking method | water cooling | |||||||
coupling | flexible | |||||||
Overdimension, mm | 3880*2150*3180 | 8470*2360*3060 | ||||||
Weight, Kg | 30000 | 35000 | 38000 |
G300 Statinary Generating Sets Main Specification | |||||||
1500GF6 | 1600GF5 | 1800GF7 | 2000GF8 | ||||
1500 | 1600 | 1800 | 2000 | ||||
1650 | 1760 | 1980 | 2200 | ||||
400/415/440/3300/6300/10500/13800 | |||||||
50 | 60 | 50 | 60 | 50 | 60 | 50 | 60 |
0.8 Lagging | |||||||
3 | |||||||
G8300ZD10 | G8300ZD8 | G8300ZD10 | G8300ZD8 | G8300ZD8 | G8300ZD8 | G8300ZD12 | G8300ZD8 |
1765 | 2000 | 1765 | 2000 | 2000 | 2000 | 2206 | 2000 |
500 | 600 | 500 | 600 | 600 | 600 | 600 | 600 |
3 phase alternator | |||||||
<0.5 | |||||||
<0.5 | |||||||
±1.0 | |||||||
20, -15 | |||||||
<0.5 | |||||||
+20, -15 | |||||||
<5 | |||||||
<4 | |||||||
automatic and munual | |||||||
manual | |||||||
compressed air | |||||||
pressue lubricating | |||||||
water cooling | |||||||
flexible | |||||||
8470*2360*3060 | |||||||
38000 | 42560 |
Remark
1. rating for the generator set is based on the following standard conditions
air temperature :25℃
total barometric pressure 100kpa
charge air coolant temperature 25℃
relative humidity 30%
If test ambient conditions are not same as the standard ambient conditions, the power and fuel consumptions should be revised according to GB/T6072.1-2000
2. The generator set can operate under overload, intermittently for 1 hour every 12h, the fuel injection quantity is usualy locked in the rated power position
GN8320 Stationary Generating Sets Main Specification |
||||||||||
Model |
2400GF |
2500GF |
||||||||
|