Advantages of our oxygen concentrator medical oxygen concentrator
1.PSA Technology
2.France CECA molecular sieve
3.Big LCD Screen
4.Time setting
5.Alarm function:
Low voltage alarm function;
Low oxygen concentration alarm function.
6.Low noise
7.Streamlined design, all plastic shell.
8.Pulley design, easy to move.
Pics for medical oxygen concentrator
1.Technical data of our medical oxygen concentrator
Model: | OLV-3 | OLV-3W | OLV-5 | OLV-5W |
Flow Rate: | 0-3L/min | 0-5L/min | ||
Input Power: | 260VA+15% | 300VA+15% | ||
Purity Oxygen: | ≥ 93%±3(V/V) | |||
Voltage: | AC220V±22V,50Hz±1Hz/AC110V±15V,60Hz±1Hz | |||
Outlet pressure: | 20kPa~60kPa | |||
Noise : | less than 45dB(A) | |||
Atomization: | ≥0.15mL/min | ≥0.15mL/min | ||
Net Weight: | 19.5kg | 22kg | ||
Dimension: | 490×270×560(mm) | |||
Warranty: | One year | |||
Standard Accessorizes: | 1× Oxygen generator 1× Power cord 2× Oxygen tube 1× Atomizer(Only atomization models) 1× Connecting tube of humidifier cup 2× Primary air suction filtering sponge 2× Secondary air suction filter 1× Instruction book 1× Warranty Card |
2.Storage and transportation requirements of our medical oxygen concentrator
Ambient temperature -20 ℃ ~ 50 ℃;
Relative humidity ≤ 95%;
Atmospheric pressure 500hPa ~ 1060hPa.
3.Scope of oxygen concentrator medical oxygen concentrator
Apply tomedical institutions,family, etc.
Preparationof oxygenforhypoxicpatients.
We can supply 3L and 5L medical oxyegn generator,welcome to contact us for more information,and we will try our best to serve you and satisfy you.
Features of our medical oxygen concentrator
1.Imported France CECA molecular sieve: Lifespan is more than 10,000 hours, which is twice of others’.
Moreover, our molecular sieve is not easy to be filled up by dusts, and maintain high efficient adsorption of nitrogen, and to make high purity oxygen.
2.Adopt pressure swing adsorption (PSA) technology of efficient molecular sieve, with simple process flow and low energy consumption.
3.Oxygen purity is 90%±3,whatever the flowrate is 1L,or 5L.
4.Alarm:
A.Power failure-:When the power is off suddenly,the machine will stop working,and send alarm signal.
If the old man use oxygen generator at night at home,such as blackouts, the family will hear alarm, timely replacement of oxygen cylinder use, which is safe.
B.Low voltage alarm:When the voltage is lower than 190V±10V/95±5V,the machine will stop working,and send alarm signal.Then,you can add a voltage stabilizing device.
5.Best silicone tube:internal pipe that oxygen going through and connecting pipes are imported from the United States of Dow Corning Corporation,
which are the best silicone material,medical-grade, durable and odorless.
6.Overload protection device:When the temperature of the compressor main winding current is too high or too large,
in order to avoid compressor motor burned, compressor overload protection device will automatically disconnect the power supply,without changing,which is more convenient.
7.Each batch of raw materials testing,each semi-finished components inspection,full inspection for each procedure.
The factory will test the machine for 36h continuously before finish,and quality inspection report make the quality be assured.
8.high altitude test,don't effect the oxygen purity: