Specifications
Brand Name :
NEWBRIDGE
Certification :
FCC,CE
Place of Origin :
SHENZHEN,CHINA
MOQ :
1PC
Price :
Negotiation
Payment Terms :
T/T , Western Union
Supply Ability :
According to the different products , the monthly output is different
Delivery Time :
According to the quantiy and stocking , 3-4 working days after payment
Packaging Details :
packing can be done by customer's requested, usually used in carton
Model Number :
ND-10SFP-LR
fiber :
single fiber
Device Type :
optical SFP Module
Data rate :
10G
Operating temperature :
0°C to 70°C
distance :
10KM
Fiber Connector :
SC,FC,ST
Description
10G 10km Bi - Directional SFP Optical Transceiver Single fiber Single Mode for DDM

Product Features

●Supports 9.95 to 10.5Gb/s bit rates

●Duplex LC connector

●Hot pluggable SFP+ footprint

●Uncooled 1310nm DFB transmitter, PIN photo-detector

●Applicable for 10km SMF connection

●Low power consumption, < 1W

●Digital Diagnostic Monitor Interface

●Optical interface compliant to IEEE 802.3ae 10GBASE-LR

●Electrical interface compliant to SFF-8431

●Operating case temperature:

Commerical:-20 to 75 °C

Industrial:-40 to 85 °C

Applications

●10GBASE-LR/LW at 10.3125Gbps

●10G Fiber Channel

●Other optical links

Product Descriptions

The transceiver Enhanced Small Form Factor Pluggable SFP+ transceivers are designed for use in 10-Gigabit Ethernet links up to 10km over SingleMode fiber. They are compliant with SFF-8431,SFF-8432 and IEEE 802.3ae 10GBASE-LR/LW. The transceiver designs are optimized for high perform-ance and cost effective to supply customers the best solutions for telecommunication.

Functional Diagram

10G 10km Bi - Directional SFP Optical Transceiver Single fiber  Single Mode with  DDM

Absolute Maximum Ratings

Parameter Symbol Min. Max. Unit Note
Supply Voltage Vcc -0.5 4.0 V
Storage Temperature TS -40 85 °C
Relative Humidity RH 0 85 %

Note: Stress in excess of the maximum absolute ratings can cause permanent damage to the transceiver.

General Operating Characteristics

Parameter Symbol Min. Typ Max. Unit Note
Data Rate Ethernet 10.3125 Gb/s
Fiber Channel 10.518
Supply Voltage Vcc 3.13 3.3 3.47 V
Supply Current Icc5 200 285 mA
Operating Case Temp. Tc 0 70 °C
TI -40 80

Electrical Characteristics (TOP(C) = -20 to 75 , TOP(I) =-40 to 85 ,VCC = 3.13 to 3.47 V)

Parameter Symbol Min. Typ Max. Unit Note
Transmitter
Differential data input swing VINPP 180 700 mVpp 1
Transmit Disable Voltage VD VCC-0.8 Vcc V
Transmit Enable Voltage VEN Vee Vee+0.8
Input differential impedance Rin 100 Ω
Receiver
Differential data output swing Vout,pp 300 850 mVpp 2
Output rise time and fall time Tr, Tf 28 2.0 Vcc+0.3 Ps 3
LOS asserted VLOS_F VCC-0.8 Vcc V 4
LOS de-asserted VLOS_N Vee Vee+0.8 V 4

Note:

1. Connected directly to TX data input pins. AC coupling from pins into laser driver IC.

2. Into 100Ω differential termination.

3. 20 – 80%. Measured with Module Compliance Test Board and OMA test pattern. Use of four 1’s and four 0’s sequence in the PRBS 9 is an acceptable alternative.

4. LOS is an open collector output. Should be pulled up with 4.7kΩ – 10kΩ on the host board. Normal operation is logic 0; loss of signal is logic 1.

Optical Characteristics (TOP(C) = -20 to 75 , TOP(I) =-40 to 85 ,VCC = 3.13 to 3.47 V)

Parameter Symbol Min. Typ Max. Unit Note
Transmitter
Operating Wavelength λ 1260 1355 nm
Ave. output power (Enabled) PAVE -6 0 dBm 1
Side-Mode Suppression Ratio SMSR 30 dB
Extinction Ratio ER 4 4.5 dB
RMS spectral width Δλ 1 nm
Rise/Fall time (20%~80%) Tr/Tf 50 ps 2
Dispersion penalty TDP 3.2 dB
Relative Intensity Noise RIN -128 dB/Hz
Output Optical Eye Compliant with IEEE 0802.3ae
Receiver
Operating Wavelength 1260 1600 nm
Receiver Sensitivity(ER=4.5) PSEN1 -13.6 dBm 3
Receiver Sensitivity(ER=6) PSEN2 -14.4 dBm 3
Average Receive Power PAVE -14.2 +0.5 dBm
Receiver Reflectance Rrx -12 dB
LOS Assert Pa -30 dBm
LOS De-assert Pd -17 dBm
LOS Hysteresis Pd-Pa 0.5 4 dB

Notes:

1. Average power figures are informative only, per IEEE 802.3ae.

2. Valid between 1260 and 1355 nm. Measured with worst ER; BER<10-12; 231 – 1 PRBS.

3. Valid between 1260 and 1355 nm. Per IEEE 802.3ae.

Pin Defintion And Functions

10G 10km Bi - Directional SFP Optical Transceiver Single fiber  Single Mode with  DDM 10G 10km Bi - Directional SFP Optical Transceiver Single fiber  Single Mode with  DDM

Pin Symbol Name/Description
1 VEET [1]

Transmitter Ground

2 Tx_FAULT [2]

Transmitter Fault

3 Tx_DIS [3]

Transmitter Disable. Laser output disabled on high or open

4 SDA [2] 2-wire Serial Interface Data Line
5 SCL [2]

2-wire Serial Interface Clock Line

6 MOD_ABS [4]

Module Absent. Grounded within the module

7 RS0 [5] Rate Select 0
8 RX_LOS [2] Loss of Signal indication. Logic 0 indicates normal operation
9 RS1 [5]

Rate Select 1

10 VEER [1]

Receiver Ground

11 VEER [1]

Receiver Ground

12 RD-

Receiver Inverted DATA out. AC Coupled

13 RD+

Receiver DATA out. AC Coupled

14 VEER [1]

Receiver Ground

15 VCCR

Receiver Power Supply

16 VCCT

Transmitter Power Supply

17 VEET [1]

Transmitter Ground

18 TD+

Transmitter DATA in. AC Coupled

19 TD-

Transmitter Inverted DATA in. AC Coupled

20 VEET [1]

Transmitter Ground

Notes:

1.Module circuit ground is isolated from module chassis ground within the module.

2.should be pulled up with 4.7k – 10k ohms on host board to a voltage between 3.15Vand 3.6V.

3.Tx_Disable is an input contact with a 4.7 kΩ to 10 kΩ pullup to VccT inside the module.

4.Mod_ABS is connected to VeeT or VeeR in the SFP+ module. The host may pull this contact up to Vcc_Host with a resistor in the range 4.7 kΩ to10 kΩ.Mod_ABS is asserted “High” when the SFP+ module is physically absent from a host slot.

5. RS0 and RS1 are module inputs and are pulled low to VeeT with > 30 kΩ resistors in the module.

Digital Diagnostic Specifications

The transceivers can be used in host systems that require either internally or externally calibrated digital diagnostics.

Parameter Symbol Units Min. Max. Accuracy Note
Transceiver temperature DTemp-E ºC -45 +90 ±5ºC 1,2
Transceiver supply voltage DVoltage V 2.8 4.0 ±3%
Transmitter bias current DBias mA 0 127 ±10% 3
Transmitter output power DTx-Power dBm -2 +3 ±2dB
Receiver average input power DRx-Power dBm -20 +1 ±2dB

Notes:

1.When Operating temp.=0~70 ºC,the range will be min=-5,Max=+75

2. Internally measured

3. The accuracy of the Tx bias current is 10% of the actual current from the laser driver to the laser

Typical Interface Circuit

10G 10km Bi - Directional SFP Optical Transceiver Single fiber  Single Mode with  DDM

Recommended power supply filter

10G 10km Bi - Directional SFP Optical Transceiver Single fiber  Single Mode with  DDM

Note:

Inductors with DC resistance of less than 1Ω should be used in order to maintain the required voltage at the SFP input pin with 3.3V supply voltage. When the recommended supply filtering network is used, hot plugging of the SFP transceiver module will result in an inrush current of no more than 30 mA greater than the steady state value

Package Dimensions

10G 10km Bi - Directional SFP Optical Transceiver Single fiber  Single Mode with  DDM

Ordering Information

Part Number Description
SFP+,9.95 to 10.5Gb/s, 1310nm, 10km, -20~75℃, with DDM
SFP+,9.95 to 10.5Gb/s, 1310nm, 10km, -40~85℃, with DDM

10G 10km Bi - Directional SFP Optical Transceiver Single fiber  Single Mode with  DDM

10G 10km Bi - Directional SFP Optical Transceiver Single fiber  Single Mode with  DDM

10G 10km Bi - Directional SFP Optical Transceiver Single fiber  Single Mode with  DDM

10G 10km Bi - Directional SFP Optical Transceiver Single fiber  Single Mode with  DDM

10G 10km Bi - Directional SFP Optical Transceiver Single fiber  Single Mode with  DDM

Send your message to this supplier
Send Now

10G 10km Bi - Directional SFP Optical Transceiver Single fiber Single Mode with DDM

Ask Latest Price
Brand Name :
NEWBRIDGE
Certification :
FCC,CE
Place of Origin :
SHENZHEN,CHINA
MOQ :
1PC
Price :
Negotiation
Payment Terms :
T/T , Western Union
Contact Supplier
10G 10km Bi - Directional SFP Optical Transceiver Single fiber  Single Mode with  DDM
10G 10km Bi - Directional SFP Optical Transceiver Single fiber  Single Mode with  DDM
10G 10km Bi - Directional SFP Optical Transceiver Single fiber  Single Mode with  DDM
10G 10km Bi - Directional SFP Optical Transceiver Single fiber  Single Mode with  DDM
10G 10km Bi - Directional SFP Optical Transceiver Single fiber  Single Mode with  DDM
10G 10km Bi - Directional SFP Optical Transceiver Single fiber  Single Mode with  DDM

Shenzhen Newbridge Communication Equipment Co.,Ltd

Active Member
8 Years
guangdong, shenzhen
Since 2004
Business Type :
Manufacturer, Exporter
Certification Level :
Active Member
Contact Supplier
Submit Requirement