GYXTY Outdoor fiber optic cable central loose tube non-armored outdoor optical cable
1. Description
GYXTY Steel Wire Armored Uni Tube Single Jacket cable is designed with the flexibility and versatility required for today's most demanding installations, including aerial, Conduit and Duct. Overall steel wire armoring provide good tensile and crush resistant.
2.Specifications
2.1 optical characteristics
Fiber Type | G.652 | G.655 | 50/125 um | 62.5/125 um | |
Attenuation | 850 nm | <3.0 dB/km | <3.3 dB/km | ||
(+20X) | 1300 nm | <1.0 dB/km | <1.0 dB/km | ||
1310 nm | <0.36 dB/km | <0.40 dB/km | |||
1550 nm | <0.22 dB/km | <0.23 dB/km | |||
Bandwidth | 850 nm | >500 MHz-km | >200 Mhz-km | ||
1300 nm | >500 MHz-km | >500 Mhz-km | |||
Numerical Aperture | 0.200±0.015 NA | 0.275±0.015 NA | |||
Cable Cut-off Wavelength cc | <1260 nm | <1450 nm |
2.2 Structure and Technical Specifications
Fiber Count | Nominal Diameter | Nominal Weight | Allowable Tensile Load (N) | Allowable Crush Resistance (N/100mm) | ||
(mm) | (kg/km) | Short Term | Long Term | Short Term | Long Term | |
2~12 | 7.5 | 74 | 3000 | 1000 | 1500 | 600 |
14~24 | 8 | 80 | 3000 | 1000 | 1500 | 600 |
Note : This datasheet can only be a reference, but not a supplement to the contract. Please contact the sales for the details.
3. We produce and test the cable complying with the following standard
Mechanical Performance | |
Max Tension Performance | IEC 60794–1-2-E |
Max. Operation Tension | IEC 60794–1-2-E1 |
Crush Test | IEC 6079 –1-2-E3 |
Impact Test | IEC 60794–1-2-E4 |
Repeated Bending | IEC 60794–1-2-E6 |
Torsion Test | IEC 60794–1-2-E7 |
Cable bend | IEC 60794–1-2-E11A |
Attenuation Coefficient | ITU-T G.652 |
Structural Test | IEC-60793-1-20 |
Environmental Performance | |
Temperature Cycling | IEC 60794–1-2-F1 |
Water Penetration | IEC 60794–1–2-F5B |
Filing Compound Flow | IEC 60794-1-E14 |
4. Packing and Shipping
Cable is supplied in lengths as specified in PI or as requirement. Each length will be shipped on a separate non-returnable wooden drum. The minimum barrel diameter of the drum will not be less than 30 times the cable diameter.
The cable on each reel will be completely covered with a thermal wrap which is fastened to the cable by packaging straps. This wrap is reusable and provides excellent thermal and UV protection.
The cable ends will be sealed with plastic protection caps to prevent water penetration. The ends will be easily accessible for testing. A final inspection test report with attenuation performance data for each fiber is attached inside the drum.
4. Our business philosophy