FTTH GPON Fiber Optic PLC Splitter ABS Box
Description
PLC (Planar Lightwave Circuit) Splitters are Single Mode Splitters with an even split ratio from one input fiber to multiple output fibers. Available split counts are: 1x4, 1x8, 1x16, and 1x32. PLC Splitters are availble with 900µm loose tube singlemode fiber and terminated or unterminated as per your needs. Unconnectorized PLC splitters come with no connectors for easy splicing or connectorization. Connectorized PLC Splitters are available with your choice of Fiber Optic Connectors: LC/UPC, LC/APC, SC/UPC, SC/APC, FC/UPC, FC/APC, and ST/UPC.
Features
Low Insertion loss
Low PDL
Compact Design
Good channel-to-channel uniformity
Wide Operating Wavelength:
From 1260nm to 1650nm
Wide Operating Temperature:
From -40℃ to 85℃
High Reliability and Stability
Application
FTTX Systems
PON Networks
CATV Links
Optical Signal Distribution
Compliance
Telcordia GR-1209-CORE
Telcordia GR-1221-COR
RoHS
Specifications
Table 1 – 1×N PLC Splitter
Parameters |
1×2 |
1×4 |
1×8 |
1×16 |
1×32 |
1×64 |
1×128 |
Operating Wavelength (nm) |
1260~1650 |
||||||
Fiber Type |
G657A1 or customer specified |
||||||
Insertion Loss (dB)(P/S Grade) |
3.8/4.0 |
7.1/7.3 |
10.2/10.5 |
13.5/13.7 |
17/17.4 |
20./20.4 |
23.8/24.2 |
Loss Uniformity (dB) |
0.4 |
0.6 |
0.8 |
1.2 |
1.5 |
2 |
2.5 |
Polarization Dependent Loss(dB) |
0.2 |
0.2 |
0.2 |
0.25 |
0.3 |
0.35 |
0.4 |
Return Loss (dB) (P/S Grade) |
55/50 |
55/50 |
55/50 |
55/50 |
55/50 |
55/50 |
55/50 |
Directivity (dB) |
55 |
55 |
55 |
55 |
55 |
55 |
55 |
Wavelength Dependent Loss (dB) |
0.3 |
0.3 |
0.3 |
0.5 |
0.5 |
0.5 |
0.5 |
Temperature Stability (-40~85 ℃)(dB) |
0.4 |
0.4 |
0.4 |
0.5 |
0.5 |
0.5 |
0.5 |
Operating Temperature (℃) |
-40~85 |
||||||
Storage Temperature (℃) |
-40~85 |
||||||
Device Dimension (mm) |
4x4x40 |
4x4x40 |
4x4x40 |
4x7x50 |
4x7x50 |
4x12x60 |
N/A |
Module Dimension (mm) |
100x80x1 |
100x80x10 |
100x80x10 |
120x80x18 |
120x80x18 |
141x115x18 |
140×115×18 |
Mini-Module Dimension (mm) |
4x4x40 |
4x7x60 |
4x7x60 |
4x12x60 |
6x20x80 |
6x40x80 |
N/A |
Table 2 – 2×N PLC Splitter
Parameters |
2×2 |
2×4 |
2×8 |
2×16 |
2×32 |
2×64 |
Operating Wavelength (nm) 1260~1650 |
|
|
|
|
|
|
Fiber Type G657A1 or customer specified |
|
|
|
|
|
|
Insertion Loss (dB)(P/S Grade) |
4 |
7.6 |
11 |
14.4 |
17.5 |
21 |
Loss Uniformity (dB) |
0.6 |
1 |
1.2 |
1.5 |
1.8 |
2.2 |
Polarization Dependent Loss(dB) |
55/50 |
55/50 |
55/50 |
55/50 |
55/50 |
55/50 |
Return Loss (dB) (P/S Grade) |
0.2 |
0.2 |
0.3 |
0.3 |
0.4 |
0.4 |
Directivity (dB) |
55 |
55 |
55 |
55 |
55 |
55 |
Wavelength Dependent Loss (dB) |
0.3 |
0.4 |
0.5 |
0.5 |
0.5 |
0.5 |
Temperature Stability (-40~ |
0.4 |
0.4 |
0.4 |
0.5 |
0.5 |
0.5 |
Operating Temperature (℃) |
-40~85 |
|
|
|
|
|
Storage Temperature (℃) |
-40~85 |
|
|
|
|
|
Device Dimension (mm) |
4x4x40 |
4x4x40 |
4x4x40 |
4x7x50 |
4x7x50 |
4x12x60 |
Module Dimension (mm) |
100x80x10 |
100x80x10 |
100x80x10 |
120x80x18 |
120x80x18 |
141x115x18 |
Mini-Module Dimension (mm) |
4x4x40 |
4x7x60 |
4x7x60 |
4x12x60 |
6x20x80 |
6x40x80 |