Specifications
Brand Name :
ESTEL
Model Number :
GPAD401M52-1A
Certification :
ISO9001, CE, 3C, FCC, TLC
Place of Origin :
Shenzhen, China (Mainland)
MOQ :
1
Price :
negotiation
Payment Terms :
L/C, T/T, D/A, D/P, Western Union
Supply Ability :
20,000 sets per month
Delivery Time :
7-10 working days
Packaging Details :
carton/wooden case
Input Voltage :
140~300VAC
Application :
Industrial Device
Input Frequency :
47~63Hz
Max. Output Current :
8A
Output efficiency :
natural cooling
Output Voltage :
DC52V
Description

Enclosed Industrial Power Supplies With Short Circuit / Overvoltage Protections

Quick Details:

Place of Origin: Shenzhen, China (Mainland) Input Voltage: 140~300VAC
Brand Name: ESTEL Output Voltage: DC52V
Model Number: GPAD401M52-1A Output Power: 400W
Product Name: Industrial Power Supplies Input Frequency: 47~63Hz
Certification: ISO9001, CE, 3C, FCC, TLC Max. Output Current: 8A
Application: Industrial Device

Payment & Shipping Terms:

Minimum Order Quantity: 1 set
Price: negotiation
Payment Terms: L/C, D/A, D/P, T/T, Western Union
Supply Ability: 20,000 sets per month
Delivery Time: 7-10 working days
Packaging Details: carton/wooden case

1. Description

The GPAD401M52-1A industrial power supply is with wide input voltage range (140 to 300Vac), with single way output. The power system is equipped with protections against output short-circuit, over-current and output over-voltage. The power supply is designed strictly in accordance with the safety regulations, which conforms to the safety standards and requirements of information technology.

2. Specifications

Technical Parameters

Ambient conditions
Parameters Min Typical Max Unit Note
Operating temperature -40 +55 °C
Storage temperature -45 +85 °C
Relative humidity 10 90 %
Altitude 3000 m
Atmospheric pressure 70 106 KPa
Cooling Natural cooling

Input
Parameter Min Typical Max Unit Note
AC input voltage range 140 220 300 Vac
AC input start voltage 155 285 Vac
AC input frequency range 47 50 63 Hz

Basic output characteristics
Parameter Min Typical Max Unit Note
Output voltage range +52 Vdc
Output voltage range 51.2 52.8 Vdc
Output current range 0 8 A
Load regulation ±1.5 %
Stabilized voltage precision ±1 %
Line regulation ±0.5 %
Noise +ripple (peak to peak value) 80 mV At rated input/output, apply 0.1uF film capacitor and 10uF/50V HF electrolyte capacitor, oscilloscope band width of 20MHz.
Output power 400 W Natural cooling/full load output
Output efficiency 87 % Rated input/output
Temperature coefficient ±0.02 %/°C
Recovery time of load effect 200 uS Load mutation, overshoot of output voltage rating of plus or minus 5% or less.
Turn on/off overshoot ±5 %

Protection
Parameter Min Typical Max Unit Note
Input over-voltage protection 310 320 Vac With 10% load
Input under-voltage protection 120 130 Vac
Output over-voltage protection 60 V
Output current-limited protection 9 12.75 A Self-recovery
Over temperature protection 95 105 °C Self-recovery
Output short-circuit protection Can be long time short-circuit and self-recovery

EMC and others
Parameter Standard and requirements
Radiation emission(CE) EN55022 - Class B
Conduction interference(RE) EN55022 - Class B
Surge EN61000-4-5 LEVEL 3 , line-line 2KV, line-earth 4KV
Atmosphere discharge (ESD) EN61000-4-2 LEVEL 3 (Criterion B)
Contact discharge(ESD) EN61000-4-2 After the shell is mounted, the discharge of the shell of the machine box does not affect the work of the power module. Contact discharge: ±6KV; Air discharge:±8KV (criterion B)
Radiated anti-interference (RS) EN61000-4-3 LEVEL 2: 3V/m Field strength
Conducted anti-interference (CS) EN61000-4-6 LEVEL 2: 3V/m Field strength
Electrical Fast Transient(EFT) IEC61000-4-4 LEVEL 3: 2KV
Voltage dips and short interruptions EN61000-4-11 drop to 70%, 40%, 0%; duration time is 10ms, 100ms, 1000ms etc
Vibration 5 ~ 9 Hz, the amplitude is 3.5 mm; 9 ~ 200 Hz, acceleration is 10 m/s2; three axial, Sweep frequency vibration 5 times in each direction (3 * 50 minutes), the power supply is not damaged.
Shock A half sine wave, the acceleration is 20 G, pulse width is 11 ms, shock axis: 3 direction X, Y, Z, shock times: 3 times in each direction.
Collision test Collision waveform: half sine wave; peak acceleration: 180m/s2; pulse width: 6ms; collision direction: 6 direction; collision frequency: 100 times in each direction.
Hydrostatic pressure test

TL=Wt×(S-1)×F×9.8(N)

Wherein: TL: applied pressure values, the unit is N; Wt: the weight of the package itself, the unit is kg; S: Allowable stacking layers numeber , select the maximum stacking layers number; F: safety coefficient, is usually 5; holding time for applying pressure is 2h.

Moisture proof GB/T2423.4-1993 alternating damp heat test, 24~45°C, 95%RH, 48h
Anti-fungal GB/T2423.16-1999 fungus test, level 2
Cooling Module naturally conduct and dissipate heat
Noise Within the scope of the input voltage and output voltage and current, at a distance 1 meter from front, back, left, right of power supply, , at a distance 1.5 meter from upper and lower of power supply, power supply noise is less than 55 DB (A)
MTBF MTBF≥100,000h
Annual return rate ≤1%
Smelling Any abnormal and poisonous smelling is not allowed
Dust proof Have certain dust function

Safety and insulation grade
Parameter Requirement Note
Input –output 1500Vac/10mA//1min No arc, no breakdown, put off discharge tube when testing
Input –earth 1500Vac/10mA//1min
Output –earth 500Vdc/10mA//1min
Ground resistance <0.1Ω
Insulation resistance ≥10MΩ In normal atmospheric pressure, when relative humidity is 90%, testing voltage is 500VDC, the insulating resistance of input-output, input-grounding, output-grounding are all ≥10MΩ
Contact current <1.75mA For a single power supply, contact current < 1.75 mA
Ground resistance <0.1Ω For a single power supply, Ground resistance <0.1Ω.

Mechanical specifications
L×W×H (mm) As below figure
Weight(kg) ≤0.9Kg

Enclosed Industrial Power Supplies With Short Circuit / Overvoltage Protections

3. Alarm

Enclosed Industrial Power Supplies With Short Circuit / Overvoltage Protections

Alarm signal
Items Yes / no Technical indication Notes
Power down alarm signal Yes

When normal input, output low impedance;

When the power off, output high impedance

AC input fails, output +52V, in the case of full load, alarm signal is up to + 2.2 V (test need to add pull resistance); when +52V drop to +38 V, time interval shall not be less than 1 ms
Normal input LED display Yes Using indicator light(red): red light is on, input is normal
Normal output LED display Yes Using indicator light(green): green light is on, output normal 52V
Output on/off control Yes Output switch controller controls internal power supply protection circuit signal electric potential by rocker switch on the panel to achieve output power off and on.

Note:

1. The power indicator light is required to install on the PCB board ( in the same side of the input and output socket), the red light on the input, the green light on the output.

2. Alarm port circuit requirements: when input power is normal, optocoupler conduction (saturation), alarm port output low impedance . When input power is down, Optocoupler cutoff, IN OK port output high impedance, and the driving current of alarm port need reach 10mA.

4. Packing and Shipping

Enclosed Industrial Power Supplies With Short Circuit / Overvoltage Protections

Our Delivery Agent

The goods can be shipped by sea, by air, by courier, by land, by train, etc.

Besides the following delivery agent, we can also look for the delivery agent with the best price in china if you need us to do for you.

5. Our Contact Information

Mobile Phone: 0086-13752765943

Telephone: 0086-0755 66600941

Email: info@estel.com.cn

lxf.estel@hotmail.com
Skype: fiona.liang10

Send your message to this supplier
Send Now

Enclosed Industrial Power Supplies With Short Circuit / Overvoltage Protections

Ask Latest Price
Brand Name :
ESTEL
Model Number :
GPAD401M52-1A
Certification :
ISO9001, CE, 3C, FCC, TLC
Place of Origin :
Shenzhen, China (Mainland)
MOQ :
1
Price :
negotiation
Contact Supplier
Enclosed Industrial Power Supplies With Short Circuit / Overvoltage Protections
Enclosed Industrial Power Supplies With Short Circuit / Overvoltage Protections
Enclosed Industrial Power Supplies With Short Circuit / Overvoltage Protections
Enclosed Industrial Power Supplies With Short Circuit / Overvoltage Protections

Tianjin Estel Electronic Science and Technology Co.,Ltd

Verified Supplier
10 Years
guangdong, shenzhen
Since 2002
Business Type :
Manufacturer, Distributor/Wholesaler, Exporter
Total Annual :
15 Million-20 Million
Employee Number :
101~200
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement