Specifications
Brand Name :
ESTEL
Model Number :
ET9090210-EQ2D
Certification :
ISO9001, CE, 3C, FCC, TLC, IP55
Place of Origin :
Shenzhen, China (Mainland)
MOQ :
1
Price :
negotiation
Payment Terms :
T/T, L/C, DA, DP, etc
Supply Ability :
7,200 sets per month
Delivery Time :
Aboout 20 working days
Packaging Details :
wooden case + wooden plinth
Cabinet Layout :
one bay for 19'' equipment
Structure :
sandwich structure panel, double wall with heat insulation
Coating :
anti-corrosion outdoor powder coating
Protection :
dustproof, sunproof and rainproof
Cooling System :
1500W AC220V air conditioner+DC48V fans
Material :
galvanized steel
Size :
H×W×D 2100×900×900mm
Protection Level :
IP55
Lock :
anti-theft three point lock (support padlock)
Grounding Protection :
copper bar
Door :
one front door + one back door
IP grade :
IP55
Description

Anti Corrosion Powder Coated Thermostatic Outdoor Telecom Cabinet With Front and Rear Access

1. Cabinet drawing

Anti Corrosion Powder Coated Thermostatic Outdoor Telecom Cabinet With Front Rear AccessAnti Corrosion Powder Coated Thermostatic Outdoor Telecom Cabinet With Front Rear Access

2. Cabinet Applications

The cabinet is suitable for outdoor environment, such as road side, park, building roof, mountain area, flat ground, etc.

The cabinet can be installed with base station equipments, power supply equipments, batteries, temperature control equipments, transmission equipments and other equipments, or the cabinet can reserve installation space and heat exchange capacity for the above equipments, providing reliable mechanical and environmental protection for normal operation of the internal equipments.

The cabinet is mainly used in wireless communication base station, such as 4G, communication/network integrated service, access/transmission switching station, emergency communication/transmission

3. Cabinet Features

  • The cabinet is weatherproof, such as sun-proof, dust-proof and waterproof, which is used in outdoor environment.
  • Cabinet cooling: air conditioner and auxiliary direct ventilation fans. MTBF≥50000h.
  • Cabinet load bearing: ≥600kg
  • Ingress protection: IP55( we can also support IP65)
  • The layout of the cabinet is reasonable, which will facilitate cable access, fixing and grounding. There are entrance holes individually for power cable, signal cable and optical cable.
  • All the cables used in the cabinet are made from flame retardant materials.
  • The cabinet includes grounding bar.
  • Surface treatment: degreasing, derusting, rustproof phosphating (or galvanizing), powder coated.
  • Flame retardance: comply with GB5169.7 test A
  • Insulation resistance: the insulation resistance between grounding devices and cabinet body parts is not lower than 2×104M/500V(DC).
  • Withstand voltage: the withstand voltage between grounding devices and cabinet body parts is not lower than 3000V(DC)/1min.
  • Mechanical strength: each surface can bear upright pressure >980N; after the door is open, its outer end can bear upright pressure >200N.

In a word, our Energy Saving Integrated Cabinet can provide complete solutions for outdoor working environment and safety management of telecom base station. As a base station, it can integrate the main equipments, system power supply, AC and DC power distribution, environment monitoring, batteries, lightning protection and grounding devices. As functional cabinet (battery cabinet, power supply cabinet, transmission cabinet etc.), it can help telecom carriers to realize easy station obtaining, energy saving, fast deployment.

4. Cabinet Advantages Introduction

Anti Corrosion Powder Coated Thermostatic Outdoor Telecom Cabinet With Front Rear Access

5. Cabinet Specifications

(1) Technical Parameters

Item Type Technical Parameter
Structure Dimension

External Dimension: W×D×H 900×900×2100mm

Internal Dimension: W×D×H 800×800×1800mm

Layout 1 compartment
Equipment Installation Method 19” rack
Door With one front door and one back door, and anti-theft three point lock for outdoor cabinet (support padlock)
Material Galvanized steel, sandwich structure panel, double wall with heat insulation
Heat Insulation There are heat insulation between inner wall and outer wall.
Ingress Protection IP55
Temperature Control Cooling AC220V 50Hz air conditioner and DC48V fans
Lightning Proof Grade B lightning proof Nominal: 60KA, Max.: 100KA
Lighting LED lamp 48V LED lamps (immovable), with protective circuit breaker
Temperature Temperature Working Temperature: -40°C ~ +55°C
Storage Temperature: -50°C ~ + 70°C
Transport Temperature: -50°C ~ +70°C
Humidity Relative Humidity 5% ~ 100%
Pressure Air Pressure 62kpa ~ 101kpa (similar to 0m ~ 5000m altitude)
Radiation Intensity Solar Radiation Intensity 1120 ×(1±5%)W/m2

(2) Configuration List

No. Item Quantity Unit Specs
1 Outdoor Telecom Cabinet 1 Set

(1) External Dimension:W×D×H 900×900×2100mm

Internal Dimension: W×D×H 800×800×1800mm

(2) One compartment: equipment compartment

(3)With one front door and one back door , and anti-theft three point lock for outdoor cabinet (support padlock)

(4) Material: galvanized steel, sandwich structure panel, double wall with heat insulation

(4.1) Cabinet left side, right side and back: sandwich structure panel, outer plate: 0.5mm galvanized steel, inner plate: 0.5mm galvanized steel, insulation: 45mm flame retarded EPS.

(4.2) Cabinet door and base: outer plate: 1.5mm galvanized steel , inner plate: 0.8mm galvanized steel, insulation: 40mm PEF.

(4.3) Cabinet roof: sandwich structure panel (outer plate: 0.5mm galvanized steel, inner plate: 0.5mm galvanized steel, insulation: 45mm flame retarded EPS. ) + 1.0mm galvanized steel.

2 Air Conditioner 1 Set

Cooling capacity: 1500W,

Power supply: AC220V, 50HZ,

Model:TC06-150JFH/01

3 Auxiliary Direct Ventilation Fans 2 PC DC48V
4 Environment Monitoring Unit 1 Set

19", 1U; Power Supply: DC48V

Support RS485 and TCP/IP communication interface

5 Water Sensor 1 PC
6 Smoke Sensor 1 PC
7 Temperature and Humidity Sensor 1 PC
8 Door Sensor 2 PC One for controlling LED lamp, the other for open door alarm
9 LED Lamp 1 PC DC48V
10 Power Distribution Unit 1 Set

Grade B Lightning Proof

AC Input: 63A/2P *1;

AC Output: 16A/1P*4;

DC Output: 16A/1P*4

Input Voltage: AC220V.

11 Package 1 Set Wooden Case

6. Cabinet Details Introduction

6.1 Components Installation

  • LED lamp, LED lamp sensor, smoke sensor and door sensor are installed at the top of the cabinet.
  • Environment monitoring unit and PDU are installed on 19” rack.
  • Water sensor is installed at the bottom of the cabinet.
  • Temperature and humidity sensor is installed at the side inside the cabinet.
  • Air Conditioner and fans are installed on the door of the cabinet.

Anti Corrosion Powder Coated Thermostatic Outdoor Telecom Cabinet With Front Rear Access

Anti Corrosion Powder Coated Thermostatic Outdoor Telecom Cabinet With Front Rear Access

Anti Corrosion Powder Coated Thermostatic Outdoor Telecom Cabinet With Front Rear Access

Anti Corrosion Powder Coated Thermostatic Outdoor Telecom Cabinet With Front Rear Access

6. 2 Cable Entry

Feeder cable and other external cables all use bottom wiring method.

Anti Corrosion Powder Coated Thermostatic Outdoor Telecom Cabinet With Front Rear Access

6.3 Grounding Protection

  • The cabinet includes grounding copper bar with anti-corrosion coating. There are enough screws for wiring connection terminals.
  • The metal part of the cabinet should be interconnected and be connected with grounding bar. Connection resistance between any two points is lower than 0.1Ω.
  • Protective earthing of other equipments inside the cabinet should be connected to the grounding bar

Anti Corrosion Powder Coated Thermostatic Outdoor Telecom Cabinet With Front Rear Access

6.4 Door lock theft proof design

Damage resistance of the theft proof lock meets GA/T 73-1994 “Mechanical Anti-theft Lock” class B requirement, supporting padlock.

Anti Corrosion Powder Coated Thermostatic Outdoor Telecom Cabinet With Front Rear Access

Three point lock

Anti Corrosion Powder Coated Thermostatic Outdoor Telecom Cabinet With Front Rear Access

6.5 Door Connection and Fastening

The cabinet use inside door hinges,inside installation,inside fixing, no outer screws and embedded cabinet door, these design can protect cabinet against the theft and water access. Use anti-loose threaded connection as structure and bearer connection. Anchor bolt for fixing cabinet use hot dip galvanized bolts.

Anti Corrosion Powder Coated Thermostatic Outdoor Telecom Cabinet With Front Rear Access

6.6 Surface Treatment

The surface of cabinet is made of special outdoor anticorrosive powder coating, the color is grey.

7. Cabinet Pictures

Anti Corrosion Powder Coated Thermostatic Outdoor Telecom Cabinet With Front Rear AccessAnti Corrosion Powder Coated Thermostatic Outdoor Telecom Cabinet With Front Rear Access

8. Cabinet Wooden Case Packing

Anti Corrosion Powder Coated Thermostatic Outdoor Telecom Cabinet With Front Rear Access

Send your message to this supplier
Send Now

Anti Corrosion Powder Coated Thermostatic Outdoor Telecom Cabinet With Front Rear Access

Ask Latest Price
Brand Name :
ESTEL
Model Number :
ET9090210-EQ2D
Certification :
ISO9001, CE, 3C, FCC, TLC, IP55
Place of Origin :
Shenzhen, China (Mainland)
MOQ :
1
Price :
negotiation
Contact Supplier
Anti Corrosion Powder Coated Thermostatic Outdoor Telecom Cabinet With Front Rear Access
Anti Corrosion Powder Coated Thermostatic Outdoor Telecom Cabinet With Front Rear Access
Anti Corrosion Powder Coated Thermostatic Outdoor Telecom Cabinet With Front Rear Access
Anti Corrosion Powder Coated Thermostatic Outdoor Telecom Cabinet With Front Rear Access

Tianjin Estel Electronic Science and Technology Co.,Ltd

Verified Supplier
10 Years
guangdong, shenzhen
Since 2002
Business Type :
Manufacturer, Distributor/Wholesaler, Exporter
Total Annual :
15 Million-20 Million
Employee Number :
101~200
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement