AC220V Outdoor Enclosure Air Conditioner RS485 Communication Interface
AC220V 50Hz 500W Outdoor Cabinet Air Conditioner Remote Monitor RS485 Communication Interface
1. Outdoor cabinet air conditioner introduction
The air conditioner is one kind of refrigeration product self-developed for cabinet. It is applicable in the place where the cabinet internal heat is very large, the internal electronic equipment is sensitive to the environment temperature and which should be isolated internally and externally completely. This product has multiple functions, high reliability, and has the feature that it can start to work without complex debugging after powering.
2. Technical data
Item | Name | Unit | Parameter |
Dimension and installation | Body outline dimension (height*width*depth ) | mm | 550*320*169 |
Outline dimension including flange(height*width*depth ) | mm | 582*352*169 | |
Weight | Kg | 12.7 | |
Installation method | Door Mounted | ||
Application environment | Outdoor | ||
Environment and protection | Working environment temperature | ℃ | -40 to +55 |
Noise | dB(A) | 54 | |
IP grade | IP55 | ||
Refrigerant | R134a | ||
ROHS certification | yes | ||
Performance | Input voltage range | 220±15%VAC~50Hz | |
Refrigerating capacity(L35/L35) | W | 500 | |
Rated Refrigerating input power(L35/L35) | W | 285 | |
Rated Refrigerating current (L35/L35) | A | 1.3 | |
Maximum Refrigerating current | A | 1.95 | |
Heat capacity(optional) | W | 500 | |
Air Volume of Inner Circulation | m3/h | 120 |
The environment of outdoor cabinet is dusty and humid, in order to ensure the clean environment of equipment, it is necessary to use air conditioner to isolate the inside of cabinet from the outside environment. Prevent the entry of foreign matters. At the same time, it can prevent the equipment from being damaged by overheating. Ensure that the equipment has a good operating environment.
4. Feature
(1) Compact structure and small volume
(2) Using famous compressor, because the cabinet air conditioning is generally need to work for a long time, the compressor requirements for air conditioning are very high.
(3) Environmental refrigerant
(4) Low noise
(5) Microcomputer digital display: the cabinet belongs to the unattended type. In order to remotely view the operation status of the equipment and the cabinet temperature, and avoid manually starting the air conditioner on site and setting the temperature point, the air conditioner cabinet has the functions of setting the cabinet temperature, fault code display, low voltage, overheat and over-current fault protection and alarm, etc.
5. Installation Size Drawing
6. Air Conditioner Picture
7. Production Process