Specifications
Brand Name :
PhyMetrix
Model Number :
PGA920
Place of Origin :
CHINA
MOQ :
1
Payment Terms :
T/T
Delivery Time :
1-2Weeks
Application area :
Class I , Div.I, Groups B, C, D.
name :
O2 CO2 analyzer
Resolution :
0.1ppm or 0.01%
Repeatability Error :
≤±1%F.S.
Size :
138*185*112 (w * d * h)
Response Time :
0.15S
Technology :
CO2 in NDIR Technology
O2 Sensor :
Galvanic Cell using patented week acid electrolyte
Description

High Sensitivity Oxygen And Carbon Dioxide Analyzers / Trace Moisture Analyzer

General Description

The PGA 920 Muti-Gas Analyzer is designed too provide continuous,unattended monitoring of both oxygen and carbon dioxide or sulfur hexafluride(SF6) and trace moisture.

The focal point of the PGA-920 is its state-of-the -art sensor technologies .The oxygen sensor is an extended life electrochemical sensor with enhanced electrolyte system.This sensor provided exceptional accuracy and stability.Enhanced electrolyte system retards passivation of the sensor anode by allowing the products of oxidation to dissolve in the electrolyte.In effect,the sensor is renewed continuously resulting in a significant increase in sensor life.In addition,the enhanced mechanical design of the sensor helps to ensure long life and virtually eliminates leakage of electrolyte,a nagging(and expensive) problem assosiated with other types of sensors.PhyMetrix has complemented its oxygen measuring capabilities with a next generation NDIR sensor.The cabon dioxide sensor incorporates closed-loop control for enhanced long-term calibration stability.The control signal is generated by means of an optical referencing element that monitors source intensity.This methodology,coupled with a novel source homogenizing gas sampling chamber,yields a system with greatly improved tolerance to changes in the infrared source outputs.

High Sensitivity Oxygen And Carbon Dioxide Analyzers / Trace Moisture Analyzer

Technical indicators

Measuring range 0~5000PPM; 0~5%; 0~20%; 0~100% (optional sensor)
display 3-digit digital LCD display
Resolution 0.1PPM or 0.01%
Preheat time <2minutes (starting time) <30minutes (meet technical specifications)
Linear error ≤±2%F.S. (which does not include calibration error)
Repeatability error ≤±1%F.S.
Response time T90 is about 0.15S (@1SCFH)
sensor type NDIR infrared dual optical wavelength sensor
Operating temperature 32~104F (0~40°C)
environment humidity 0~85%, no condensate
Rechargeable battery power AC115~230V
Application area Class I , Div.I, Groups B, C, D.
size 138*185*112 (w * d * h)
weight 2.45Kg

Send your message to this supplier
Send Now

High Sensitivity Oxygen And Carbon Dioxide Analyzers / Trace Moisture Analyzer

Ask Latest Price
Brand Name :
PhyMetrix
Model Number :
PGA920
Place of Origin :
CHINA
MOQ :
1
Payment Terms :
T/T
Delivery Time :
1-2Weeks
Contact Supplier
High Sensitivity Oxygen And Carbon Dioxide Analyzers / Trace Moisture Analyzer
High Sensitivity Oxygen And Carbon Dioxide Analyzers / Trace Moisture Analyzer

Beijing york instrument

Active Member
7 Years
beijing, beijing
Since 1992
Business Type :
Manufacturer
Total Annual :
15000000-20000000
Employee Number :
50~100
Certification Level :
Active Member
Contact Supplier
Submit Requirement