Ethylene Oxide Electrochemical Gas Detector Analyzer 4ETO-100 CLE-1222-400
4ETO-100 CLE-1222-400 Ethylene Oxide Electrochemical Gas Sensor
Features:
Performance characteristics:
Load 2000 ppm
Sensitivity 0.02 ± 0.01 µA/ppm
Baseline (20 oC) < ± 0.2 µa
Baseline drift equivalent to 0 to 10 ppm (-20 oC to 50 oC)
Resolution 10 ppm
Response time (T90) 70 seconds
linearity
Long-term stability < 2% signal value per month
Working condition
Operating temperature -20 o
C to 50 oC
Operating humidity 15 to 90%RH (no condensation)
Working pressure 90 to 110 kPa
The bias is 0 mV
Storage time 6 months (in box)
Storage temperature 0 oC to 20 oC
Service life 2 years in the air
Physical property
It weighs about 5 grams
Specifications:
Working pressure | 90 to 110 kPa |
Operating temperature | -20 oC to 50 oC |
Response time | (T90) 70 seconds |
Resolution | 10 ppm |