Product Description:
4CM 2112B2055 Carbon Monoxide Gas Sensor Is Used In The Mobile Life Safety Field
Features:
measurement
Working principle: electrochemistry, three electrodes
Measurement range :0-2000ppm
Filter: acid gas
Filter capacity: > 20,000 PPM per hour
Sensitivity: 70 + 15 na/PPM
Response time :≤10s 20℃
Resolution: < 1ppm
Recovery time: < 90s(usually < 30s)
Baseline offset (clean air): < ±2ppm CO
Zero drift (20-40℃): < 9ppm
Repeatability: < ±2% CO
Linearity: within 2000ppm
Electric parameters:
Load resistance :5 ω
Resolution: < 1ppm
Bias voltage: No requirement
Weight: 5 g
Shell material: modified polyphenyl ether
Typical applications
Mobile, life safe
Operating temperature :-40-50℃
Specifications:
The use of temperature | - 40-50 ℃ |
The temperature coefficient of | See the data |
Operating pressure range | 800-1200 mBar |
humidity | 15-90% RH of condensation |