Product Description:
GS-UVB-3535LQC UVB Photodiode UV-B Lamp Monitoring UV-B Radiation Dose Measurement
Features:
General Features:
l Selective response to UVB+UVC band
l Photovoltaic mode operation
l SMD 3535 ceramic package with quartz window
l High responsivity and low dark current
Applications:
UV-B lamp monitoring, UV-B radiation dose measurement
Specifications: Parameters Symbol Value Unit Maximum ratings
Operation temperature range Topt -25-85 oC
Storage temperature range Tsto -40-80 oC
Soldering temperature (3 s) Tsol 260 oC
Reverse voltage Vr-max -10 V
General characteristics (25 oC) Chip size A 1 mm2 Dark current (Vr = -5 V) Id <1 nA Temperature coefficient (@265 nm) Tc 0.05 %/ oC Capacitance (at 0 V and 1 MHz) Cp 18 pF> <1 nA Temperature coefficient Tc 0.065 %/ oC Capacitance (at 0 V and 1 MHz) Cp 1.7 pF>
<1 nA Temperature coefficient (@265 nm) Tc 0.05 %/ oC Capacitance (at 0 V and 1 MHz) Cp 18 p>
Specifications:
Wavelength of peak responsivisity | λ p 290 nm |
Peak responsivisity (at 385 nm) | Rmax 0.129 A/W |
Spectral response range (R=0.1×Rmax) | 230-325 nm |
UV-visible rejection ratio (Rmax/R450 nm) | - >10 - |