Product Description:
GT-UV405-LW GaN UV Sensor Is Used For UV Smoke Detection In UV Aging Box
Features:
Indium Gallium Nitride Based Material
l Photovoltaic mode operation
l TO-46 metal housing
l High responsivity and low dark current
UV index monitoring, UV radiation dose measurement, flame detection
Parameters Symbol Value Unit Maximum ratings
Operation temperature range Topt -25-85 oC
Storage temperature range Tsto -40-85 oC
Soldering temperature (3 s) Tsol 260 oC
Reverse voltage Vr-max -10 V
General characteristics (25 oC) Chip size A 1 mm2 Dark current (Vr = -1 V) Id
<1 nA Temperature coefficient (@365 nm) Tc -0.1 %/ oC Capacitance (at 0 V and 1 MHz) Cp 26 pF>
Specifications:
Specifications | Parameters |
Peak wavelength | 355nm |
Light sensitivity | 0.218A/W |
Spectral response range (R=0.1×Rmax) | - 220-410 nm |
UV-visible rejection ratio (Rmax/R400 nm) | - >10 |