Product Description:
4H2-1000 CLE-0613-400 0 To 1000 PPM Electrochemical Hydrogen Sensor
Features:
The working conditions
Operating temperature :-20 ℃ to 50 ℃
Operating humidity :15 to 90%RH (non-condensing)
Working pressure :90 to 110 kPa
Bias: 0 mV
Storage time :6 months (in special packaging box)
Storage temperature :0 ℃ to 20 ℃
Service life: 2 years in air
Warranty: 12 months after delivery
Physical properties of
Weight: about 5 grams
Location requirements: None
Specifications:
Gas | concentration (PPM) | Output signal (equivalent to PPM H2) |
Hydrogen sulfide | 24 | 0 |
Sulfur dioxide | 5 | 0 |
Nitric oxide | 35 | 10 |
Nitrogen dioxide | 5 | 0 |
Carbon monoxide | 50 | 200 |
Ethylene | 100 | 80 |
Hydrogen | 10 | 0 |