4H Hydrogen Sulfide (H2S) Gas Sensor Part Number: AC200-800 Improved performance variability
The cross sensitivity data shown below does not form part of the
product specification and is supplied for guidance only. Values quoted are based on
tests conducted on a small number of sensors and any batch may show significant
variation. For the most accurate measurements, an instrument should be calibrated
using the gas under investigation.
* Specifications are valid at 20°C, 50% RH and 1013 mBar, using City Technology recommended
circuitry. Performance characteristics outline the performance of sensors supplied within the
first 3 months. Output signal can drift below the lower limit over time.
Storage Life | 6 months in sealed container |
Expected Operating Life | 2 years in air |
Recommended Storage Temp | 0 to 20°C |
Long Term Output Drift | < 2% signal drift / month |
Operating Humidity Range | 15% to 90% RH non-condensing |