Specifications
Model Number :
ME4-H2S
MOQ :
1
Payment Terms :
L/C, D/A, D/P, T/T, Western Union, MoneyGram
Delivery Time :
3-5work days
Detection Range :
0~100ppm
Max range :
500ppm
Sensitivity :
(0.8±0.15)µA/ppm
Resolution :
0.1ppm
Response Time(T90) :
<30S
Bias Voltage :
0mV
Description

ME4-H2S Hydrogen Sulfide Gas Sensor Oxidation-reduction Reaction With Hydrogen Sulfide And Oxygen Take Place Respectively On The Working Electrode And On The Counter Electrode

ME4-H2S hydrogen sulfide gas sensor is constant potential electrolysis type. Oxidation-reduction reaction with hydrogen sulfide and oxygen take place respectively on the working electrode and on the counter electrode. The process releases electric charge and generates current. The current is in direct proportion to the concentration of hydrogen sulfide. So the concentration of the target gas could be got by measuring the value of current.

Features :

Low power consumption, high precision, high sensitivity, wide linear range, good anti-interference ability, excellent repeatability and stability.

Main applications:

It is used for hydrogen sulfide detection in industrial occasions, mine and environmental protection field.

Stability(/month) <2﹪
Output Linearity Linear
Zero drift(-20℃~40℃) ≤0.2ppm
Temperature range -20℃~50℃
Humidity range 15﹪~90﹪RH

ME4-H2S Hydrogen Sulfide Gas Sensor Oxidation-reduction Reaction With Hydrogen Sulfide And Oxygen Take Place Respectively On The Working Electrode And On The Counter Electrode

Send your message to this supplier
Send Now

ME4-H2S Hydrogen Sulfide Gas Sensor Oxidation-reduction Reaction With Hydrogen Sulfide And Oxygen Take Place Respectively On The Working Electrode And On The Counter Electrode

Ask Latest Price
Model Number :
ME4-H2S
MOQ :
1
Payment Terms :
L/C, D/A, D/P, T/T, Western Union, MoneyGram
Delivery Time :
3-5work days
Detection Range :
0~100ppm
Max range :
500ppm
Contact Supplier
ME4-H2S Hydrogen Sulfide Gas Sensor Oxidation-reduction Reaction With Hydrogen Sulfide And Oxygen Take Place Respectively On The Working Electrode And On The Counter Electrode
ME4-H2S Hydrogen Sulfide Gas Sensor Oxidation-reduction Reaction With Hydrogen Sulfide And Oxygen Take Place Respectively On The Working Electrode And On The Counter Electrode
ME4-H2S Hydrogen Sulfide Gas Sensor Oxidation-reduction Reaction With Hydrogen Sulfide And Oxygen Take Place Respectively On The Working Electrode And On The Counter Electrode

ShenzhenYijiajie Electronic Co., Ltd.

Verified Supplier
3 Years
guangdong, shenzhen
Since 2006
Business Type :
Manufacturer, Trading Company
Total Annual :
900000-1000000
Employee Number :
50~80
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement