Specifications
Model Number :
AC400-R00A-CIT
MOQ :
1
Payment Terms :
L/C, D/A, D/P, T/T, Western Union, MoneyGram
Delivery Time :
3-5work days
Measurement Range :
0.5 ppm H2S to 200 ppm H2S
Maximum Overload :
500 ppm
Onboard Filter :
None
Sensitivity* :
175 nA/ppm ±35 nA/ppm
T90 Response Time* :
Typically < 30 seconds
Recovery Time* (from 200 ppm to <4 ppm) :
< 180 seconds
Description

AC400-R00A-CIT Electrochemical Hydrogen Sulfide (H2S) Analogue Gas Sensor For Hydrogen Sulfide Gas Analyzer

Document Purpose
The purpose of this document is to present the performance specification of the 1series 1H2S hydrogen sulfide gas sensor.
This document should be used in conjunction with the 1H2S Characterisation Note, the Operating Principles (OP08), and the Product Safety Datasheet (PSDS 5).
For guidance on sensor performance outside of these limits, please refer to the 1H2S Characterisation Note.
Output signal can drift below the lower limit over time. For guidance on the safe use of the sensor, please refer to the Operating Principles (OP08).

Poisoning
Gas sensors are designed for operation in a wide range of environments and harsh conditions. However, it is
important that exposure to high concentrations of solvent vapours is avoided during 1) storage, 2) fitting into
instruments and 3) operation.
When using sensors with printed circuit boards (PCBs), degreasing agents should be used before the sensor is
fitted.
Do not glue directly on or near the sensor as the solvent may cause crazing of the plastic.

Baseline Offset* (in clean air) < ±0.5 ppm H2S equivalent
Baseline Shift (-40°C to 60°C) < ±3 ppm H2S equivalent
Repeatability* < ±5% of measured value
Linearity* (0 ppm H2S to 200 ppm H2S) Linear ±5%
Recommended Load Resistor 5 Ω to 10 Ω
Weight < 5 g
Outer Plastic Body Material Modified PPO
O-ring Material FKM75 ±5 shore A

AC400-R00A-CIT Electrochemical Hydrogen Sulfide (H2S) Analogue Gas Sensor  For Hydrogen Sulfide Gas Analyzer

Send your message to this supplier
Send Now

AC400-R00A-CIT Electrochemical Hydrogen Sulfide (H2S) Analogue Gas Sensor For Hydrogen Sulfide Gas Analyzer

Ask Latest Price
Model Number :
AC400-R00A-CIT
MOQ :
1
Payment Terms :
L/C, D/A, D/P, T/T, Western Union, MoneyGram
Delivery Time :
3-5work days
Measurement Range :
0.5 ppm H2S to 200 ppm H2S
Maximum Overload :
500 ppm
Contact Supplier
AC400-R00A-CIT Electrochemical Hydrogen Sulfide (H2S) Analogue Gas Sensor  For Hydrogen Sulfide Gas Analyzer
AC400-R00A-CIT Electrochemical Hydrogen Sulfide (H2S) Analogue Gas Sensor  For Hydrogen Sulfide Gas Analyzer
AC400-R00A-CIT Electrochemical Hydrogen Sulfide (H2S) Analogue Gas Sensor  For Hydrogen Sulfide Gas Analyzer
AC400-R00A-CIT Electrochemical Hydrogen Sulfide (H2S) Analogue Gas Sensor  For Hydrogen Sulfide Gas Analyzer
AC400-R00A-CIT Electrochemical Hydrogen Sulfide (H2S) Analogue Gas Sensor  For Hydrogen Sulfide Gas Analyzer
AC400-R00A-CIT Electrochemical Hydrogen Sulfide (H2S) Analogue Gas Sensor  For Hydrogen Sulfide Gas Analyzer

ShenzhenYijiajie Electronic Co., Ltd.

Verified Supplier
3 Years
guangdong, shenzhen
Since 2006
Business Type :
Manufacturer, Trading Company
Total Annual :
900000-1000000
Employee Number :
50~80
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement