Product Description:
ME4-CO Electrochemical Carbon Monoxide Sensors Are Used In Petroleum, Petrochemical Metallurgical Mining And Other Industrial Sites
Features:
ME4-CO type sensor is a constant potential electrolysis type CO sensor. The corresponding REDOX reaction of CO and O2 occurs on the working electrode and the opposite electrode respectively, and the charge is released to form a current. The current generated is proportional to the concentration of CO. The concentration of CO can be determined by testing the current size.
Item parameter
Detection gas Carbon monoxide (CO)
Measuring range 0-1000ppm
z Maximum measurement limit 1500ppm
Sensitivity (0.080±0.02) uA/ppm
Resolution 1ppm
Response time (T90) ≤25s
Bias voltage 0mV
Load resistance (recommended) 10Ω
Repeatability < 2% output value
The output linearity is linear
Stability (/ month) < 5%
Zero drift (-20℃-40℃) 9ppm
Temperature range -20℃~50℃
Humidity range 15% to 90%RH
Pressure range standard atmospheric pressure ±10%
Detection life 2 years (in the air)
Specifications:
Response time (T90) | ≤25S |
Load resistance (recommended) | 10Ω |
Repeatability | < 2% output value |
Zero drift | (-20℃ ~ +40℃) 9ppm |