Specifications
Model Number :
FCM2630-C01
MOQ :
1
Payment Terms :
L/C, D/A, D/P, T/T, Western Union, MoneyGram
Delivery Time :
3-5work days
Target gases :
Refrigerant gas R-32
Circuit voltage :
5.0±0.2V DC
Output voltage :
3.50V typical in 5000ppm R-32 Malfunction condition: VOUT < 0.05V or VOUT > 4.95V (Vc = 5.00V)
Reference voltage :
3.50±0.10V at 20˚C Malfunction condition: VREF < 2.50V or VREF > 3.70V (Vc = 5.00V)
Initial alarm accuracy :
2800~7000ppm R-32 (under standard test conditions) Alarm state: VOUT ≥ VREF Normal state: VOUT < VREF
Warm-up time :
≤60 seconds (time before VOUT < VREF after power is turned on in a clean atmosphere)
Description

FCM2630-C01 Gas Sensor Module Pre-calibrated Module Is Used For Refrigerant Leak Detection In Refrigeration Systems Refrigerant Gases R-32 Factory Calibrated Analog Output

Features:

* Factory calibrated
* Temperature compensation circuit
* Resistant to interference gases
* Analog output
* Meets IEC60335-2-40 and JRA4068 requirements

Applications:

* Refrigerant gas leak detection in air
conditioning/refrigeration systems

FCM2630-C01* is an embedded type module using the semiconductor gas
sensor TGS2630 which is optimized to detect A2L refrigerant gas R-32.
This module enables users to easily build a reliable gas leakage detection
system by eliminating electronic circuit design for temperature compensation
and the calibration process. In addition, a connector allows easy replacement
of the gas sensor module for periodic maintenance.
The TGS2630 gas sensor has a built-in filter to reduce the influence of alcohol
and other interference gases, resulting in high selectivity to R-32. For more
detailed information on the gas sensor, including sensitivity characteristics,
see TGS2630 Product Information.
FCM2630-C01 is capable of satisfying the IEC60335-2-40 Edition 6.0 Annex LL and the JRA4068:2021
(Performance 3) standards. The applicable standards are both limited to refrigerant gas type R-32.
* FCM Series is the model name of refrigerant gas sensor modules supplied by Figaro Engineering Inc.

Power consumption approx. 0.3W
Weight approx. 4g
Dimensions 25 x 25 x 16mm
Test gas conditions 20˚±2˚C, 65±5%RH
Circuit conditions Vc = 5.00±0.05V DC

FCM2630-C01 Gas Sensor Module Pre-calibrated Module Is Used For Refrigerant Leak Detection In Refrigeration Systems Refrigerant Gases R-32 Factory Calibrated Analog Output

Send your message to this supplier
Send Now

FCM2630-C01 Gas Sensor Module Pre-calibrated Module Is Used For Refrigerant Leak Detection In Refrigeration Systems Refrigerant Gases R-32 Factory Calibrated Analog Output

Ask Latest Price
Model Number :
FCM2630-C01
MOQ :
1
Payment Terms :
L/C, D/A, D/P, T/T, Western Union, MoneyGram
Delivery Time :
3-5work days
Target gases :
Refrigerant gas R-32
Circuit voltage :
5.0±0.2V DC
Contact Supplier
FCM2630-C01 Gas Sensor Module Pre-calibrated Module Is Used For Refrigerant Leak Detection In Refrigeration Systems Refrigerant Gases R-32 Factory Calibrated Analog Output
FCM2630-C01 Gas Sensor Module Pre-calibrated Module Is Used For Refrigerant Leak Detection In Refrigeration Systems Refrigerant Gases R-32 Factory Calibrated Analog Output
FCM2630-C01 Gas Sensor Module Pre-calibrated Module Is Used For Refrigerant Leak Detection In Refrigeration Systems Refrigerant Gases R-32 Factory Calibrated Analog Output
FCM2630-C01 Gas Sensor Module Pre-calibrated Module Is Used For Refrigerant Leak Detection In Refrigeration Systems Refrigerant Gases R-32 Factory Calibrated Analog Output
FCM2630-C01 Gas Sensor Module Pre-calibrated Module Is Used For Refrigerant Leak Detection In Refrigeration Systems Refrigerant Gases R-32 Factory Calibrated Analog Output

ShenzhenYijiajie Electronic Co., Ltd.

Verified Supplier
3 Years
guangdong, shenzhen
Since 2006
Business Type :
Manufacturer, Trading Company
Total Annual :
900000-1000000
Employee Number :
50~80
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement