DC Power Distribution Unit Rack-mount Terminal Box

DCPD-8

Description:

- DC Power Distribution Unit DCDP-8 is a device used to control and distribute electric power for indoor low voltage DC power contribution system. Mounted in a rack cabinet and connected between the -48V DC power supply and the protected equipment, it can protect the equipment from surge and instantaneous over voltage caused by the outside environment (lightning, electromagnetic radiation interference, etc.) or by the internal subsystems (switching effect, start and stop operation of inductive and capacitive loads)

- Power Distribution Unit (PDU) Rack-mount Terminal Box is used for low-voltage DC power distribution.

- The DCPD-8 PDU Rack-mount Terminal Box is standard 19'' rack mount box, it can install in a standard 19'' cabinet.

- The DCPD-8 PDU Rack-mount Terminal Box is installed between a power supply source and system equipment. It protects the system from electrical pulse and instant over-voltage caused by lightning strike, electromagnetic radiation interference, system switch on/off, or inductive / capacitive load on / off.

- The DCDP-8 PDU Rack-mount Terminal Box is used for distributed base stations, providing power to BBUs and RRUs.

- The DCDP-8 PDU Rack-mount Terminal Box structure port:

* 2 channels DC power inputs are of the rated current value of 160 A.

* 10 channels DC power outputs configure 25 A power breakers.

* 10 channels DC power outputs possess the capability of lightning protection.

Feature:

- Two path of power input, and ten paths of power output for distribution with lightning protection.

- Large current-through capacity and low residual voltage.

- Built-in lightning protection board performs lightning and surge protection on the first power-down LLVD1 output.

- Maximum power input current of 50A, 100A, 160A, and maximum rated current of 10A or 25A for power output.

- Remote signalling alarm interface (dry contact signal).

- IP20 protection degree provided by metal enclosure.

- Indoor Installation with good fire resistance.

- Front leading-out cabling with little space occupation.

- 19 inch 1U rack installation.

- 1 input and 8 outputs.

- Circuit breaker for 8 outputs, can disconnect the circuit when fault or overload happens.

- Easy connection for inputs and outputs wiring.

- Insulation of output connectors.

- Large current discharge capability and low residual voltage.

Specification:

- PWR1 & PWR2: Receives external DC power input (Inside dual DC-input ends are connected together in parallel with the rated current of 160 A).

- Switch (breaker 10*25 A): Controls DC power output.

- DC output (BBU/RRU): Provides power supply for the power distribution module of an indoor Base Band Unit (BBU) or an outdoor Remote Radio Unit (RRU).

- LP_ALM: Provides lightning protection alarm (dry contact output).

Technical Data:

- Nominal operating voltage Uo: 48V DC

- Operating voltage range: 0-75VDC

- Frequency: 0Hz

- Power Input: Voltage: -48VDC. Current: 160A.

- Power Output: Voltage: -48VDC

- Current:

Configuration of power breaker: 10 channels DC power outputs with 25A power breakers.

Configuration of ligntning protection: 10 channels DC power outputs with lightning protection.

- Monitoring:

Link up: The lightning protection module is enabled.

Link down: The lightning protection module is disabled.

- Protection modes: -48V—RTN, -48V—PE, RTN—PE

Nominal discharge current In (8/20 us waveform):

Differential-mode: -48V—RTN:10kA;

Common-mode: -48V—PE:15kA; RTN—PE:15kA

- Rated load current IR: 1 Input: 125A. 8 outputs: Max. current 25A for each output.

- Limiting voltage: -48V—RTN≤500V

- Connection: Serial connection

- Distribution capacity: 1 input and 8 outputs

- Rated current of breaker: 25A(for each output)

- Connector:

Input: Support two-hole cold press terminals

Output: Spring crimping connectors

- Wire area: Input: 16~25mm². Output: 1~10mm².

- Grounding connection: By M6 screw

Environment Request:

-Operating environment:

Operating temperature: 0℃~+55℃

Relative humidity: 10%~95%

Atmosphere pressure: 70kPa~106kPa

- Storage environment:

Storage temperature: -40℃~+80℃

Relative humidity: 5%-95%

Atmosphere pressure: 70kPa~106kPa

Size & Weight:

Size: 485*45*120mm

Net Weight: 1.80kg

Gross Weight: 2.00kg

OEM/ODM Service:
- If you want to show your own brand LOGO on the goods such as cable, package bag, label or any where. Our OEM and ODM service is always ready to do it. Please contact with our sales team to get best support.

Packing:
- According to Stardard Export Packing.
- Carton box, wooden box, wooden pallet.

Shipping:
- International express such as UPS, TNT, DHL, etc
- Internatioal air: CA, AA, EA, etc
- By sea: Huyndai, COSCO, etc
- Standard export sea port: Shenzhen, Hongkong, Ningbo
- Standard export airport: Shenzhen, Hongkong, Hangzhou, Shanghai

Send your message to this supplier
Send Now

19inch Rack Mountable 160A Power Distribution Unit Terminal Box DCPD8

Ask Latest Price
Brand Name :
KCO
Model Number :
DCPD8
Certification :
CE, ISO9001
Place of Origin :
China
MOQ :
Negotiation
Price :
Negotiation
Contact Supplier
19inch Rack Mountable 160A Power Distribution Unit Terminal Box DCPD8
19inch Rack Mountable 160A Power Distribution Unit Terminal Box DCPD8

KOCENT OPTEC LIMITED

Verified Supplier
9 Years
guangdong, shenzhen
Since 2007
Business Type :
Manufacturer, Distributor/Wholesaler, Exporter, Trading Company
Total Annual :
4000000-5000000
Employee Number :
20~250
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement