Specifications
Brand Name :
Hamilton C2 ventilator Battery
Model Number :
369106
MOQ :
1
Payment Terms :
T/T, Western Union,PayPal
Delivery Time :
3-5 working days
Product name :
Hamilton C2 ventilator Battery
Type :
369106
Warranty :
90days
Color :
black
Index Terms :
Battery
Function :
Provide Power for Oxygen Concentrator L
State :
Working Fine
Nominal Voltage :
14.4v 6.6Ah 97Wh
Inventory :
In stock
Minimum purchase contract :
1pcs
Mode of transport :
Expressage
Voltage :
12.0 to 16.8VDC
Type: :
Lithium-ion,
Recharge time :
4 h minimum
Storage: :
-20 to 60 °C,  95% relative humidity
Description

Hamilton C2 ventilator Battery 14.4V 6.6Ah 97Wh Lithium Ion Battery REF 369106

Brief Introduction

HAMILTON MEDICAL recommends that the ventilator’s batteries be fully charged before you ventilate a patient. If the batteries are not fully charged and AC power fails, always pay close attention to the level of battery charge.

Two backup batteries, one standard and the other optional, protect the HAMILTON-C2 from low, or failure of, the primary power source. When the primary power source (either AC mains or a DC power supply) fails, the ventilator automatically switches to operation on backup battery with no interruption in ventilation. An alarm sounds to signal the switchover. You must silence the alarm to confirm notification of the power system change; this resets the alarm. If the optional battery (battery 2) is available and adequately charged, the ventilator switches to this battery first. When battery 2 is depleted or not installed, the ventilator switches to the standard battery (battery 1). The batteries power the ventilator until the primary power source is again adequate or until the battery is depleted. Each battery powers the ventilator typically for 2.5 h.

As a further safeguard, the HAMILTON-C2 provides a low battery alarm. It also has a capacitor-driven backup buzzer that sounds continuously for at least 2 min when battery power is completely lost.

Specification

Type: Lithium-ion,
Recharge time 4 h minimum
Storage: -20 to 60 °C, £ 95% relative humidity

  1. Batteries are charged when power is > 20 VDC. Only use of the Hamilton Medical DC adapter ensures that the internal batteries are charged.
  2. When the voltage exceeds 27.5 VDC, the device automatically switches to battery power, and continues ventilation as set.
  3. Battery revision 3 and later
  4. These specifications apply to batteries revision 3 and later. For earlier battery revisions, the following specifications apply: 10.8 VDC, 6.7 Ah, 72 Wh, 50 W typical, 150 W maximum.
  5. The listed operating times and conditions apply to batteries revision 3 and later. For earlier battery revisions, the following specifications apply: Operating time with one battery in use (with turbine in use and the following settings: C = 15 ml/cmH2O, Rate = 10 b/min, Pinsp = 10 cmH2O, PEEP = 5 cmH2O): 2.5 h minimum, 3 h typical.

Replacing the batteries

Open the battery door (3). To remove battery 1 (1), turn the retaining screw until the battery is released. To remove battery 2 (2), press on the tab, and slide the battery out of its housing. Replace with a newly charged battery.

• To ensure that the ventilator always has battery backup, keep locked battery 1 in the ventilator at all times during ventilator operation. Battery 2 may be hot swapped while the ventilator is operating.

• Because of damage of the battery door lock the batteries in the correct position.

Hamilton C2 Ventilator Battery 14.4v 6.6Ah 97Wh Lithium Ion Battery REF 369106

1 Battery 1

2 Battery 2

3 Door

Warm Tips

In order to avoid causing unnecessary trouble, please read the following carefully.

Please look through all the pictures with patience before placing orders to confirm the product is exactly you want or not as they are also an important part of the product description. What’s more, it is buyer’s responsibility to pay for all the customs fees including all taxes and duties. So it is of great necessity for you to make certain that the equipment you are ordering can be imported in to your country. Once the package leaves our factory, the shipper is not responsible for any delays any more. So please keep it in mind that be sure to check out all the relevant information before placing your orders.

If you have any questions about Hamilton C2 ventilator Battery 14.4v 6.6Ah 97Wh Lithium Ion Battery REF 369106 , please feel free to contact us at any time, we are glad to answer them.

Send your message to this supplier
Send Now

Hamilton C2 Ventilator Battery 14.4v 6.6Ah 97Wh Lithium Ion Battery REF 369106

Ask Latest Price
Brand Name :
Hamilton C2 ventilator Battery
Model Number :
369106
MOQ :
1
Payment Terms :
T/T, Western Union,PayPal
Delivery Time :
3-5 working days
Product name :
Hamilton C2 ventilator Battery
Contact Supplier
Hamilton C2 Ventilator Battery 14.4v 6.6Ah 97Wh Lithium Ion Battery REF 369106
Hamilton C2 Ventilator Battery 14.4v 6.6Ah 97Wh Lithium Ion Battery REF 369106
Hamilton C2 Ventilator Battery 14.4v 6.6Ah 97Wh Lithium Ion Battery REF 369106
Hamilton C2 Ventilator Battery 14.4v 6.6Ah 97Wh Lithium Ion Battery REF 369106

China World Technology Medical Equipment Service Group

Verified Supplier
5 Years
guangdong, guangzhou
Since 2015
Business Type :
Manufacturer, Distributor/Wholesaler, Agent, Importer, Exporter, Trading Company, Seller
Employee Number :
20~50
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement