GE Marquette Mainstream CAPNOSTAT CO2 Sensor
GE Marquette Mainstream CAPNOSTAT CO2 Sensor 412340-002 ECG Machine Parts
► Brief Description
The GE Marquette Mainstream CAPNOSTAT CO2 Sensor is used in connection with the GE ECG Machine to measure the CO2 concentration data of patients for reference by medical staff. Its working principle is very simple, it mainly uses the selective absorption theory of molecules for carbon dioxide gas molecules, and the gas concentration can be measured according to the absorption intensity of light. According to the theory of selective absorption of gases, when the emission wavelength of the light source coincides with the absorption wavelength of the gas, the phenomenon of resonance absorption will occur, and the absorption intensity is related to the concentration of the gas, and the concentration of the gas can be directly measured after measuring the absorption intensity of light. It is such a connected sensor, one end of which is connected to GE's ECG monitoring equipment, and the other end is connected to the patient, and the patient's CO2 concentration data can be measured.
► Measurement
The GE Marquette CAPNOSTAT CO2 Sensor uses the mainstream method to measure the patient's end-of-breath CO2 concentration. There are three common measurement methods in healthcare settings, including mainstream, sideflow, and microfluidic measurement hands-off. This sensor is the mainstream measurement method of choice. Mainstream measurement is characterized by real-time monitoring, no time delay, and the patient's CO2 concentration can be measured directly in the main exhalation duct through the sensor. Although it needs to be fixed, the measured data is very accurate. Therefore, the GE Marquette CAPNOSTAT CO2 Sensor is a sensor device that is very suitable for clinical medicine.
► Specifications
BRAND NAME | GE |
PACKAGING | Carton |
WARRANTY | 90 Days |
PRODUCT CATEGORY | ECG Parts |
ITEM NO. | 412340-002 |
Color | Grey |
► Detailed photos
► Instructions
Before using the GE Marquette Mainstream CAPNOSTAT CO2 Sensor, please make sure that it is working properly and free of any damage. Otherwise, the measurement results will be inaccurate, and even affect the patient's life, health and safety. After use, it should also be properly cleaned and disinfected in time for continued use.However, the prescribed cleaning and disinfection reagents must be used, and it is forbidden to use unapproved reagents, otherwise the sensor may be damaged.
Thank you for your interest in GE Marquette Mainstream CAPNOSTAT CO2 Sensor 412340-002 ECG Machine Parts. If you are interested in our products, please feel free to contact me.We will happy to serve you.