Specifications
Brand Name :
GE
Model Number :
M1025230
MOQ :
1pcs
Payment Terms :
T/T(wire transfer), Western Union, Paypal
Delivery Time :
3-5 working days
Packaging Details :
Carton
Product Name :
GE Datex Ohmeda E-COP Module M1025230 For Monitoring The State Of The Heart
Brand :
GE
Part No :
M1025230
Dimensions (H x W x D) :
11.2 x 3.7 x 18.7 cm (4.4 x 1.5 x 7.4 in)
Weight :
0.35 kg (0.77 lb)
Temperature :
10 to 40°C (50 to 104°F)
Relative humidity :
10 to 90% non-condensing
MOQ :
One piece
Warranty :
90 days
Description

GE Datex Ohmeda E-COP Module M1025230 For Monitoring The State Of The Heart

The E-COP module integrates the measurement of cardiac output (CO), right ventricular ejection fraction (REF) and invasive arterial pressure (P) by thermodilution on the CARESCAPE™ monitor screen. The E-COPSv module allows additional measurement of combined venous oxygen saturation (SvO2) and central venous oxygen saturation (ScvO2). The module complies with IEC 60601-1 3rd edition.

Features of GE E-COP Module

• The module contains direct keys to the C.O. to start. Measurement and zeroing of invasive pressure channels

• A unique set of automatic CO measurement types

• Up to six COs can edit the average CO measurement.

• Hemodynamic and oxygenation calculation screen view

• Provides the following hemodynamic calculations with indexed values: CI, SV, SI, SVR, SVRI, PVR, PVRI, LVSW, LVSWI, LCW, LCWI, RCW, RCWI, RVEDV, RVEDVI, RVSW, RVSWI+RVESV and RVESVI

• Provides the following oxygenation calculations with indexed values: CaO2, CvO2, C(a-v)O2, VO2, VO2I, RQ, ATMP, VO2 calculation, VO2I calculation, O2ER, DO2, DO2I, PaO2, AaDO2, CcO2, Qs /Qt, CO calculation. and CI calculations.

• Edit calculation input data

• Trend calculation and printing

• Module insertion/removal without interrupting other monitoring. • SvO2, ScvO2, CO and REF measurements are provided by Edwards Lifesciences Corp. compatible catheters.

Specification of GE E-COP Module

Dimensions (H x W x D) 11.2 x 3.7 x 18.7 cm (4.4 x 1.5 x 7.4 in)
Weight 0.35 kg (0.77 lb)
Operating conditions
Temperature 10 to 40°C (50 to 104°F)
Relative humidity 10 to 90% non-condensing
Storage conditions
Temperature -25 to 60°C (-13 to 140°F)
Relative humidity 10 to 90% non-condensing
Waveform display
Range -30 to 300 mmHg
Scales Adjustable in 10 mmHg increments
Numerical display
Resolution 1 mmHg
Alarms Adjustable high and low alarm limits for systolic, diastolic and mean pressures
Pulse rate
Measurement range 30 to 250 bpm
Display resolution 1 bpm
Accuracy ±5% or ± 5 bpm
Invasive blood pressure
Measurement range -30 to 320 mmHg
Measurement accuracy ±4% or ±4 mmHg
Transducer sensitivity 5 µV/V/mmHg
Pressure filter 0 to 22 Hz (-3 dB) adjustable upper limit 4 to 22 Hz

GE Datex Ohmeda E COP Module M1025230 For Monitoring Heart State

Thank you so much for your attention .If you're interested in GE Datex Ohmeda E-COP Module M1025230 For Monitoring The State Of The Heart,feel free to contact us .Thank you .

Send your message to this supplier
Send Now

GE Datex Ohmeda E COP Module M1025230 For Monitoring Heart State

Ask Latest Price
Brand Name :
GE
Model Number :
M1025230
MOQ :
1pcs
Payment Terms :
T/T(wire transfer), Western Union, Paypal
Delivery Time :
3-5 working days
Packaging Details :
Carton
Contact Supplier
GE Datex Ohmeda E COP Module M1025230 For Monitoring Heart State
GE Datex Ohmeda E COP Module M1025230 For Monitoring Heart State
GE Datex Ohmeda E COP Module M1025230 For Monitoring Heart State
GE Datex Ohmeda E COP Module M1025230 For Monitoring Heart State
GE Datex Ohmeda E COP Module M1025230 For Monitoring Heart State

China World Technology Medical Equipment Service Group

Verified Supplier
5 Years
guangdong, guangzhou
Since 2015
Business Type :
Manufacturer, Distributor/Wholesaler, Agent, Importer, Exporter, Trading Company, Seller
Employee Number :
20~50
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement