Mortara Q-Stress 60-00186-01 IEC 10-lead 12pins EKG ECG Cable DLMOR-011-05 Compatible New
►Brief Introduction
The Mortara Q-Stress 60-00186-01 IEC 10-lead 12pins EKG ECG Cable with the model number DLMOR-011-05 is a specific type of ECG (Electrocardiogram) cable used with Mortara Q-Stress ECG machines. The ECG cable is an essential component used to connect the patient to the ECG machine for monitoring cardiac activity. It allows for the transmission of electrical signals from the patient's body to the ECG machine, where the signals are processed and displayed as a graphical representation of the heart's electrical activity (ECG waveform).
► Features
The cable is capable of obtaining a resting ECG .The device can interface with equipment for pulmonary evaluation. The Q-Stress has several built in exercise protocols for connection and control of exercise equipment such as treadmills and ergometers. The device can output analog ECG signals or digital QRS trigger signals for synchronizing an external device. The device will store a complete record of diagnostic quality test data from which the user can generate and review stress test reports.The device can communicate with electronic record keeping systems to obtain work lists and patient data, and to provide test result reports.
► How to use
Connect the Cable: Take the Mortara Q-Stress 60-00186-01 IEC 10-lead 12pins EKG ECG Cable DLMOR-011-05 and identify the 12-pin connector end. Align the connector with the corresponding port on the ECG machine. Ensure a secure and snug connection to prevent signal interference.
Attach Electrodes: Attach the appropriate ECG electrodes to the patient's skin according to the standard 10-lead ECG placement. The electrodes should be placed on specific locations on the chest, limbs, and torso as per medical guidelines.
Secure Connections: Once the electrodes are placed, connect them to the corresponding lead wires on the Mortara Q-Stress ECG cable. Match the color-coded leads with the electrodes (e.g., red lead to the right arm electrode, yellow lead to the left leg electrode, etc.). Ensure all connections are secure to avoid artifacts or signal loss.
Start ECG Acquisition: With the patient and cables properly connected, initiate the ECG acquisition on the Mortara Q-Stress ECG machine. Follow the on-screen prompts or manual instructions to begin recording the patient's ECG waveform.
Monitor and Interpret Results: Monitor the ECG waveform displayed on the machine's screen. Ensure that the waveform appears clear and free from artifacts. Interpret the ECG results based on standard criteria and guidelines for analyzing ECG traces.
Document and Store Data: After completing the ECG recording, document the findings in the patient's medical records. Some ECG machines may also allow you to save the data digitally for future reference and analysis.
Clean and Disinfect: After use, disconnect the ECG cable from the machine and remove the electrodes from the patient's skin.
► Specification
Lead Groups | Standard (Mason-Likar), Cabrera 12-lead |
Display Format | 3, 6, 6x2, or 12x1 channels |
Performance Standard | gain accuracy, frequency response, CMRR, system noise, dynamic range, and input impedance |
If you want to explore more details about Mortara Q-Stress 60-00186-01 IEC 10-lead 12pins EKG ECG Cable DLMOR-011-05 Compatible New , please let us know. Looking forward to receiving your early inquiry.