GE Spo2 probe 130010114 C403-01 REF DLG-011-02
GE Spo2 probe 130010114 C403-01 REF DLG-011-02 Brief Introduction
GE Spo2 probe 130010114 C403-01 REF DLG-011-02 is a key part of the blood oxygen meter and is used to monitor the blood oxygen saturation of the human body. Blood oxygen saturation refers to the ratio of oxygen to hemoglobin in the blood and is an important indicator of the body's oxygen supply.
Feature
Common blood oxygen probe materials on the market are generally made of medical silicone, PVC and other materials. The main purpose of the probe is to detect the ratio of HbO2 and Hb in human arterial blood through the probe's photoelectric sensor, and calculate the blood oxygen through an algorithm. saturation. Probe materials also have their own characteristics. Medical silicone blood oxygen probes are common blood oxygen probes on the market. They are soft, comfortable, and not easy to slip off. They are suitable for patients to monitor and wear for a long time, but their service life is relatively long. They are very short-lived, require frequent replacement, and are expensive. PVC blood oxygen probes are harder than silicone probes and are not easily deformed. The price is also relatively cheap. However, because the texture of this probe is relatively hard, it is not suitable for long-term wear and needs to be worn carefully.
Steps to use the probe
1. Check whether the finger-clip blood oxygen probe is intact, the probe head should be free of dirt, the probe's wire plug is secure, and the probe's contact surface is clean.
2. Check whether the oximeter is working normally, whether the display screen of the oximeter is normal, and whether the probe socket is clean.
3. Insert the probe socket of the oximeter into the interface of the oximeter, and ensure that the probe socket is secure.
4. Clamp the finger-clip blood oxygen probe on the patient's fingertips, ensuring that the contact surface of the probe is in contact with the patient's skin and ensuring good contact between the probe and the patient's skin.
5. Press the power on button of the oximeter, the oximeter starts to work, and the probe starts to measure the patient's blood oxygen saturation.
6. After waiting for a period of time and the oximeter displays the patient's blood oxygen saturation, you can pull out the finger-clip blood oxygen probe and put the probe back into the probe socket of the oximeter.
Parameters
Precautions when using blood oxygen probes for testing | Place the probe on a clean, dry skin area to avoid skin moisture affecting light penetration and reflection. |
The probe should be fixed and stable to avoid movement or shaking to ensure measurement accuracy. | |
Before each use, check whether the probe is working properly to ensure that the light intensity is stable and the reflected signal quality is good. |
Product Details Picture
Thank you for taking the time to pay attention to our product GE Spo2 probe 130010114 C403-01 REF DLG-011-02.
If you have any other questions about this product, you can contact us to answer your questions. In addition, if you want to know more about monitors, electrocardiographs, defibrillators, ventilators and accessories for various medical equipment and machines, you can contact us. We are mainly engaged in medical equipment and medical machine accessories. .
Regarding the after-sales issues of the goods, our warranty is 90 days. The goods will be carefully inspected and packaged before they are sent out to ensure that you receive satisfactory goods. Check the goods as soon as possible after you receive the goods. If you have any questions, please contact us. Contact us at any time.