According to the model of the defibrillator, select the corresponding model of pacing board to maximize the pacing function of the defibrillator and maintain the longest service life of the defibrillator. The pacing function of the defibrillator is mainly used to restore normal heart rhythm through electrical stimulation when the heart has stopped or slowed down.
Metrax Primedic M240 DM1 defibrillator pace plate is composed of very complex electronic components. Its pacing function is mainly used to restore normal heart rhythm through electrical stimulation when the heart stops or slows the heart rate. which use computer chips to control frequency intensity. It mainly stimulates the myocardium through the conduction of wire electrodes and is a multi-unit system. It is mainly used to treat ventricular fibrillation. Using the pacing function on the defibrillator can correct arrhythmia and help restore the normal beating of the heart.The pacemaker sends tiny electrical pulses to the heart to stimulate the heart when needed. It is mainly used for patients with persistent third-degree atrioventricular block, or for overspeed pacing to treat ectopic tachyarrhythmia, which is helpful for improving the heart rate. It has a blood pumping function and has a definite effect in reducing the symptoms of dizziness, dizziness and syncope in patients. Thereby promoting the excitement and contraction of the heart, correcting the symptoms of abnormal heart rate and rhythm, and treating cardiac dysfunction.
1. Preparation: Make sure the defibrillator is in working condition and connected to the corresponding power source or battery. Check that the defibrillator's electrodes are properly connected and make sure they are in good contact with the patient's skin.
2. Determine heart rhythm: Use electrocardiogram monitoring equipment to detect and record heart rhythm to ensure that the patient requires electroshock therapy.
3. Set the appropriate energy: Select the appropriate shock energy according to the patient's condition. The specific energy depends on the model of defibrillator used.
4. Safety measures: Make sure there are no conductive objects around patients and medical staff, and ensure that medical staff do not come into direct contact with patients.
5. Electric shock operation: If using a handle-type electrode, ensure a good grip and press the electrode trigger button to allow current to pass through the patient's heart. If using patch electrodes, follow the instructions of the device and stick the two electrodes on the patient's chest in sequence, press the defibrillation button to release electrical energy and deliver an electric shock to the patient's heart. In the event of arrhythmia, cardiac arrest, etc., you need to go to the hospital in time and operate the defibrillator under the operation of a professional doctor. During the operation, you need to continuously monitor the patient's heart rhythm and observe whether the electric shock therapy has restored the normal heart rhythm.
Be applicable: | Primedic M240 DM1 Defibrillator Pace Plate 19026 |
Model: | Pace Plate |
Material: | Polymer materials, metal materials, ceramic materials and nanomaterials |
MOQ: | one piece |
Imported product registration standards: | YZB/GER 1059-2011 "Defibrillator" |
Application scope: | ICU, private clinic, hospital |
Working humidity: | 10%~90% |
Package: | Safe packaging |
We default to express delivery by DHL. We will contact you as soon as possible when sending express delivery. If you have any questions after receiving the express delivery, please feel free to contact us at any time.