The defibrillator printer is composed of multiple components, each of which assumes different functions and roles. The print head is one of the most critical components in a printer. It is responsible for converting electronic signals into actual printed output. The print head is usually composed of fine nozzles, and printing is achieved by controlling the position and quantity of ink jets. The quality and precision of the print head directly affect the clarity and quality of printing. Ink cartridges or ink sacs are containers that hold ink and are used to provide the ink needed for printing. The quality and color saturation of the ink determines the outcome of the print. Ink cartridges are often replaceable, allowing the user to choose a different color of ink if needed or replace spent ink. The paper cassette or tray holds paper for use by the printer. The paper transfer unit is the component that transports paper from the paper cassette to the print head. They usually have rollers or drive belts that smoothly transport the paper to the printing position.
1. First, after confirming that the printer is turned off, open the cassette from the marked position on its rear.
2. Fix the assembled detection rods on each hole of the cassette one by one. Be careful not to install the detection rods in the wrong direction in the front, rear and up and down directions.
3. After making sure that the detection rod is firmly fixed, slowly move the cassette until the detection rod is completely pressed against the reflector and the cable is in a natural position.
4. Check whether the detection rod is flat and firm, and whether the gap between it and the machine is appropriate.
Defibrillator printing process: Automatically run self-test when starting cardioserv → Set the energy device to the ECG position → Set the energy selector to 360 Joules → Press the ②charging button on the defibrillator board → The defibrillator makes a sound and displays Stored energy →Press ③ key at the same time to discharge→The instrument automatically ejects paper
Item name | Metrax Primedic M240 DM1 Defibrillator Printer |
Brand | Primedic |
Model | printer |
Use place | Hospital Devices; Medical Care; ICU; |
Deliver time | 3-5 days |
Warranty | 90 days |
Quality Standard | Comply with international production standards |
Assembly | Print head, roller, ink cartridge, paper card slot |
We default to express delivery by DHL. We will contact you as soon as possible when sending express delivery. If you have any questions after receiving the express delivery, please feel free to contact us at any time.