GE MAC800 ECG Machine Front Panel with Screen
► About GE MAC800 ECG Machine Front Panel with Screen
The front panel of the GE MAC800 ECG machine features a small screen that displays important information during an ECG test.
This display allows medical professionals to view the patient's ECG waveform in real time for accurate monitoring and diagnosis. Heart rate, patient data and other relevant information are also displayed.
The top cover also serves as a protective layer for the internal components of the ECG device, protecting them from possible damage or interference. They are usually made of durable materials such as plastic or metal to ensure their longevity and reliability.
Product Name | GE MAC800 ECG Machine Front Panel with Screen
|
Brand | GE |
Application | GE MAC800 ECG Machine |
Condition | Used |
MOQ | One piece |
Warranty | 90 days |
► Device Maintenance
This device is designed to require only periodic inspection and cleaning for proper operation. Additional maintenance must be performed by qualified GE Healthcare service personnel.
CAUTION: ELECTRIC SHOCK HAZARD: Improper handling during inspection or cleaning may result in electric shock. To avoid possible downloads, always follow these guidelines:
• Before inspecting or cleaning the device, turn it off, disconnect it from the mains power supply, and remove the battery.
• Do not immerse any part of the device in water.
► Equipment inspection
Perform a visual inspection daily, preferably before using the equipment for the first time each day. During inspection, ensure that your device meets the following minimum requirements:
• No cracks or other damage to the case or screen.
• All plugs, cables, cords, and connectors are free of kinks, fraying, or other damage.
• All cables and connectors are securely connected.
• All buttons and controls work properly. If there is anything that requires repair, please refer the repair to an authorized service person. Discontinue use of the device until proper repair is performed.
► clean the device
Clean the exterior of your device at least once a month, and as often as needed. Cleaning Materials Used Use the following materials to clean your device.
• Neutral dish detergent
• A clean soft cloth.
• Waterfall
► Clean the device surface
Surfaces Use the following steps to clean the surfaces of your device. 1. Make a cleaning solution by diluting mild dish detergent with water.
2. Dip a clean cloth into the solution and wring out the excess.
3. Thoroughly wipe the surface of the device with a damp cloth. Do not spill solutions or liquids on the burner assembly. Avoid contact with vents, plugs, or open connectors.
4. Repeat steps 2 and 3 as necessary until the surface is sufficiently clean.
5. Wipe the surface with a clean, dry cloth or paper towel.
► Detailed Photo
Thank you so much for your attention .If you're interested in GE MAC800 ECG Machine Front Panel Cover Casing With Screen ,feel free to contact me .