Dash5000 GE Refurbished Used Patient Monitor For Hospital And Clinic
Main features:
① Optimize the monitoring design of all maintenance applications.
② Advanced algorithms are applicable to all monitoring parameters
③ Fully flexible alarm settings allow individual monitoring
④ Obtain wired or wireless ECG
⑤ Bright bedside warning lights help quickly locate patients in critical situations
⑥ A variety of installation solutions and a wide range of accessories ensure simple and flexible workplace design
⑦ 3 waveform screens to maximize the parameter value and waveform size
⑧ iTouch Pad convenient maintenance area remote control, which can be operated on either side of the bed, direct access to frequently used functions
⑨ Remote viewing via DashPort2 for the best central overview
⑩ CO2 modules and extensions to include additional Rac parameters
⑪ Broad interface options for iConnect solutions
⑫ Mainstream and low lateral flow CO2 measurement options, suitable for neonatal to adult applications
Display
Size | 12.1” |
Disply Type | Active-matrix color LCD |
Resolution | 800 x 600 dpi |
Number of traces | 7 (maximum) |
Number of seconds/trace | 4.9 at 25 mm/sec |
Sweep speed | 6.25, 12.5, 25 mm/sec (with erase bar) |
Control
Alarm
ECG
• Provide standard leads I, II, III, V, aVR, aVL and aVF
• 3 lead I, II or III
• 5-lead I, II, III, V, AVR, AVL and AVF
• 10-lead I, II, III, AVR, AVL, AVF, VI, V2, V3, V4, V5 and V6
• Simultaneous analysis of leads I, II, III and V (multi-lead mode)
• Potential customers fail to identify failed prospects
• Alarm user-selectable upper and lower heart rate limits
Pulse oximeter
• Monitoring parameters: arterial blood oxygen saturation (SpO2) and periPHiliphhiliperal blood oxygen saturation
Pulse rate (PPR)
• SpO2 range Nellcorrr 1-100%; Massimo 30-100%; GE Ohmeda 30-100%
• PPR range Nellcorrr 20-300 BPM; Masima 25-240 BPM; GE Ohmeda 30-250
• Accuracy The actual accuracy depends on the probe. Please refer to
• Manufacturer's specifications.
• Nellcorrr SpO2 ± 2 digits (70-100% SpO2)
• Masima SpO2 ± 2% adult/child (70-100% SpO2)
• GE Ohmeda SpO2 ± 2% (70-100% SpO2), SpO2 ± 3% for newborns, ≤ 69%
Unspecified
• PPR ± 3 times/minute
• Alarm User-selectable upper and lower limits of SpO2 and PPR