The product is Drager Primus Anesthetic Machine ILCA2 Sensor 6870840, which is brand new and original. When you find the product, please ensure that it can be used on your end and the model is correct. It is a sensor applied to the Drager Primus Anesthesia Machine ILCA2 machine. In the anesthesia machine, Sensor 6870840 measures expiratory flow rate, inspiratory flow rate, expiratory pressure, inspiratory pressure PEEP. This series is a ceramic substrate mounted high stability piezoresistive pressure sensor chip, which uses thin film resistors on the ceramic substrate for zero degree correction, zero temperature compensation, and sensitivity temperature compensation, and is driven by a constant voltage source.
This sensor utilizes thin film resistors on a ceramic substrate for zero degree correction, zero temperature compensation, and sensitivity temperature compensation, and is driven by a constant voltage source. SM9541 supports I2C data reading and can set a baud rate of 4Mhz.
Micro pressure range: (250pxH2O,500pxH2O,1000pxH2O,2500pxH2O2)
Wide temperature compensation range: -5 ℃ to 65 ℃ 3) Accuracy: ± 1% 4)
High performance and stable silicon chip packaging with zero calibration and temperature compensation
For anesthesia machines, the sensing part needs to be very sensitive in order to accurately measure the patient's inhalation and exhalation, as well as the anesthesia gas transmitted into the airflow. So, sensors that can sense differential pressure or airflow at a very low rate should be chosen. The Sensor 6870840 is capable of measuring the peak of a patient's breathing or the inflection point between inhalation and exhalation. Once the pressure, airflow, and medium requirements are determined, accuracy and stability requirements, including the total error band, should be considered. Consider design factors that are smaller in size, more aesthetically pleasing, and more portable. Customer calibration functionality may also need to be considered, especially for CPAP (Continuous Positive Respiratory Pressure) applications, to maximize product performance and best match the patient's breathing patterns.
Type: | Drager Primus Anesthetic Machine ILCA2 Sensor 6870840 |
Warranty period: | 90 Days |
Shipping Date: | 3-5 Working Days |
MODLE: | 6870840 |
Storage temperature: | -20-70°c |
MOQ: | 1 PCS |
COLOR: | White |
Delivery Date: | 3 - 5 Working Days |
Package | Carton |
The company has been professionally operating various brands of original medical monitoring instruments since 2015. The company has many professional senior engineers and has sufficient ability to undertake various medical equipment maintenance work. Covering motherboards, sensors, probes, modules, connectors, shells, etc. for various medical monitoring equipment.
We default to express delivery by DHL,Fedex, We will contact you as soon as possible when sending express delivery. If you have any questions after receiving the express delivery, please feel free to contact us at any time.