ECG machine is one of the most common diagnostic tools in clinical practice, which is a technique that uses an electrocardiograph to record the electrical activity changes generated by the heart during each cardiac cycle from the body surface. In each cardiac cycle, the pacemaker, atrium and ventricle are excited successively. With the change of bioelectricity, various forms of potential change patterns are drawn from the body surface through the electrocardiograph. During the use of the electrocardiograph, ECG Leadwire Set Base 10 Grabber - AHA PN 2104749-001, It needs to be used in conjunction with an electrocardiogram machine. The GE ECG Leadwire Set Base 10 Grabber - AHA PN 2104749-001 consists of 20 clips and wires of different colors, which can effectively stabilize the locations that need to be monitored.
► Wearing method:
① V1 lead (brown/red): Place the V1 electrode in the fourth intercostal space at the right edge of the sternum
② V2 lead (brown/yellow): Place the V2 electrode in the fourth intercostal space at the left edge of the sternum
③ V3 lead (brown/green): Place the V3 electrode in the middle of positions V2 and V4
④ V4 lead (brown/blue): Place the V4 electrode on the midline of the clavicle at the fifth intercostal space
⑤ V5 lead (brown/orange): Place the V5 electrode at the anterior axillary line, at the same level as V4
⑥ V6 lead (brown/red): Place the V6 electrode at the midline of the axilla, at the same level as V4 and V5. ⑦ LA lead (black): Place the LA electrode on the left shoulder
⑧ LL lead (red): Place the LL electrode on the lower edge of the chest cavity or on the horizontal line of the navel at the midpoint of the clavicle RL lead (green): Place the RL electrode on the lower edge of the chest cavity or on the horizontal line of the navel at the midpoint of the clavicle RA lead (white): Place the RA electrode on the right shoulder
Type: | GE ECG Leadwire Set Base 10 Grabber - AHA PN 2104749-001 New Original |
Warranty period: | 90 Days |
Shipping Date: | 3-5 Working Days |
MODLE: | 2104749-001 |
Storage temperature: | -20-70°c |
MOQ: | 1 PCS |
COLOR: | White |
Delivery Date: | 3 - 5 Working Days |
Package | Carton |
The company has been professionally operating various brands of original medical monitoring instruments since 2015. The company has many professional senior engineers and has sufficient ability to undertake various medical equipment maintenance work. Covering motherboards, sensors, probes, modules, connectors, shells, etc. for various medical monitoring equipment.
We default to express delivery by DHL,Fedex, We will contact you as soon as possible when sending express delivery. If you have any questions after receiving the express delivery, please feel free to contact us at any time.