A normal defibrillator board, the part behind its display screen that can be twisted can be understood as a monitor. As long as it is powered, it can work to detect electrocardiogram, blood oxygen, etc. It has a motherboard, EL LCD display driver board or blood oxygen board, ECG board, interface for connecting to the printer, and interface for connecting to the defibrillator board. Damage to these boards can result in inability to display and incomplete parameters.
The working principle of this printing motherboard is to receive printing signals through system instructions, and then print out everything that needs to be printed.
If the print head motherboard and its corresponding printing accessories malfunction, the defibrillator cannot print anything.
There are also several types of malfunctions that may occur, such as not feeding paper during printing
If this problem occurs, it is likely to be a mechanical malfunction, such as a paper feeder failure or something falling into the feeder. The printing component needs to be opened. Generally, the opening of the paper feeder of a printer is large and facing upwards. When used in the office of medical personnel, small foreign objects such as pins can easily fall into the feeder, causing the printing to fail to feed.
For example, after the defibrillator machine is turned on, the power indicator light flashes, the error indicator light does not light up, the buzzer sounds an alarm, and no printing operation is performed.
If this error occurs, it means that the printer did not detect the ink cartridge, which may be due to the ink cartridge not being properly installed. Please check it. If the ink cartridge and functions are installed on the printer, but the power indicator flashes, the error indicator light does not light up, and the buzzer sounds an alarm, then check if the ink cartridge is installed correctly
Open the front cover of the printer and check the ink cartridge on the printer carriage located at the right end of the printer. Please check from the side. If there is a gap between the rear plane of the ink cartridge and the carriage bracket, turn off the power of the defibrillator and reinstall the ink cartridge as required.
Type: | PHiliphh HeartstarXL+Defibrillator printer Interface Board |
Warranty period: | 90 Days |
Shipping Date: | 3-5 Working Days |
MODEL: | KALEX3K188 453564081231 |
Storage temperature: | -20-70°c |
MOQ: | 1 PCS |
COLOR: | GRAY |
Delivery Date: | 3 - 5 Working Days |
Package | Standard export packaging |
The company has been professionally operating various brands of original medical monitoring instruments since 2015. The company has many professional senior engineers and has sufficient ability to undertake various medical equipment maintenance work. Covering motherboards, sensors, probes, modules, connectors, shells, etc. for various medical monitoring equipment.
We default to express delivery by DHL,Fedex,etc.We will contact you as soon as possible when sending express delivery. If you have any questions after receiving the express delivery, please feel free to contact us at any time.