Specifications
Brand Name :
Physio-Control
Model Number :
11101-000016
MOQ :
One piece
Payment Terms :
T/T, Western Union,Paypal
Delivery Time :
3-5 working days
Packaging Details :
Carton
Product Name :
11101-000016 Physio-Control Infant Child Reduced Energy Defibrillation Electrodes for LIFEPAK 1000 Defibrillator
Part No :
11101-000016
Brand :
Physio-Control
Application :
LIFEPAK 1000 Defibrillator
MOQ :
One piece
Warranty :
90 days
Patient Type :
Child/Infant
Condition :
Original new
Delivery Method :
DHL,Fedex ,UPS
Description

Physio-Control Infant Child Reduced Energy Defibrillation Electrodes 11101-000016 for LIFEPAK 1000 Defibrillator

About LIFEPAK 1000 Defibrillator

MODES OF OPERATION

You can use the LIFEPAK 1000 defibrillator for:

• Automated external defibrillation (AED mode)

• Manual defibrillation therapy (Manual mode) (Requires ECG display option)

• ECG monitoring (ECG mode) (Requires ECG display option)

Basic steps for using the LIFEPAK 1000 defibrillator

1 Make sure the patient is in cardiopulmonary arrest (the patient should be unresponsive, not breathing normally, and showing no signs of circulation).

11101-000016  Physio-Control Infant Child Reduced Energy Defibrillation Electrodes for LIFEPAK 1000 Defibrillator

2 Press ON/OFF to turn on the defibrillator (the green LED will be on). You will hear voice prompts to guide you through the save process.

11101-000016  Physio-Control Infant Child Reduced Energy Defibrillation Electrodes for LIFEPAK 1000 Defibrillator

3 Prepare the patient for therapeutic electrode placement.

11101-000016  Physio-Control Infant Child Reduced Energy Defibrillation Electrodes for LIFEPAK 1000 Defibrillator

• If possible, lay the patient on a hard surface away from standing water. • Remove clothing from the patient's upper body.

• Remove excess hair from the electrode sites. If shaving is necessary, avoid cutting the skin.

• Clean the skin and dry it vigorously with a towel or gauze.

• Do not apply alcohol, benzoin, or antiperspirants to your skin.

4 Open the therapy electrode package and remove the electrodes. Slowly remove the protective sheath from the electrodes, starting at the connector end of the cable. Discard the liner safely to prevent slippage.

5 Place the therapy electrodes on the patient's chest. Starting at one end, press the electrodes firmly into the patient's skin as shown.

11101-000016  Physio-Control Infant Child Reduced Energy Defibrillation Electrodes for LIFEPAK 1000 Defibrillator

6 Connect the electrodes to the defibrillator (if they are not already connected).

7 Follow the screen messages and voice prompts provided by the defibrillator.

With Infant/Child pads:

The following specifications apply from 25 to 175 ohms.

Energy Accuracy (into 50 ohms): Selected energy ¸ 4 +/- 15%;

86 joules +/- 15% maximum Rated energy output is the nominal delivered energy based on the energy setting and patient impedance, as defined in the following chart.

11101-000016  Physio-Control Infant Child Reduced Energy Defibrillation Electrodes for LIFEPAK 1000 Defibrillator

Specification of Physio-Control Infant Child Reduced Energy Defibrillation Electrodes 11101-000016 for LIFEPAK 1000 Defibrillator

Product Name Physio-Control Infant Child Reduced Energy Defibrillation Electrodes 11101-000016 for LIFEPAK 1000 Defibrillator
Brand Physio-Control
Part No 11101-000016
MOQ One piece
Warranty 90 days
Use for Lifepak 1000 defibrillator

Thank you so much for your attention .If you're interested in 11101-000016 Physio-Control Infant Child Reduced Energy Defibrillation Electrodes for LIFEPAK 1000 Defibrillator,feel free to contact us .Thank you .

Send your message to this supplier
Send Now

11101-000016 Physio-Control Infant Child Reduced Energy Defibrillation Electrodes for LIFEPAK 1000 Defibrillator

Ask Latest Price
Brand Name :
Physio-Control
Model Number :
11101-000016
MOQ :
One piece
Payment Terms :
T/T, Western Union,Paypal
Delivery Time :
3-5 working days
Packaging Details :
Carton
Contact Supplier
11101-000016  Physio-Control Infant Child Reduced Energy Defibrillation Electrodes for LIFEPAK 1000 Defibrillator
11101-000016  Physio-Control Infant Child Reduced Energy Defibrillation Electrodes for LIFEPAK 1000 Defibrillator
11101-000016  Physio-Control Infant Child Reduced Energy Defibrillation Electrodes for LIFEPAK 1000 Defibrillator
11101-000016  Physio-Control Infant Child Reduced Energy Defibrillation Electrodes for LIFEPAK 1000 Defibrillator

China World Technology Medical Equipment Service Group

Verified Supplier
5 Years
guangdong, guangzhou
Since 2015
Business Type :
Manufacturer, Distributor/Wholesaler, Agent, Importer, Exporter, Trading Company, Seller
Employee Number :
20~50
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement