Hello, thank you for browsing our company's light bulb products. The light bulb is Halogen Lamp PN 705-0840 12V 20W for Hitachi 7060, 7080, 7160, 7180, 7050, 7040, 7020, 7350 Biochemical Analyzer. The Hitachi series biochemical analyzer has precise and fast analytical capabilities. There are various methods for project analysis, and the detection results are fast and accurate. If there are abnormal results, the real-time re inspection function and anti cross contamination function are adopted. The optical detection system with good stability is used, and the detection results have high accuracy, high precision, and high repeatability. When you are sure that the light bulb needs to be replaced, please turn off the instrument power and switch, hold the compartment door of the light bulb with your fingers, lift it up to remove the light bulb, and pay attention to the connected wiring. Please wear professional gloves to replace the light bulb, otherwise the glass outer wall of the bulb will be stained, affecting the lighting use of the biochemical analyzer.
Hitachi part number: 705-0840
Type: Halogen lamp
Voltage: 12V
Power: 20W
Compatible instruments: Hitachi 7020, 7040, 7050, 7060, 7080, 7160, 7180, 7350
1. Restore the filter to its original position. If the light source lamp ages, the light intensity will deviate from the measurement range of the photometer. When using the rate method for analysis, it may be difficult to test correctly due to excessive noise. Therefore, it is necessary to regularly replace the light source lamp Checking the light bulb is a very important thing. Please regularly check the use of the light bulb when using the biochemical analyzer to ensure that it is not affected by light source issues.
2. Remove the radiator filter screen; Use a vacuum cleaner to remove dust from the filter screen; If the filter screen is abnormally dirty, it can be rinsed with tap water. Then thoroughly dry the water or cool it thoroughly;
.
3.If you encounter any technical problems during the replacement process, please keep in touch with us at any time or find a local repair engineer to solve any problems you may have.
Type: | Halogen lamp PN 705-0840 12V20W, suitable for Hitachi 7060, 7080, 7160, 7180, 7050, 7040, 7020, 7350 biochemical analyzer |
Warranty period: | 90 Days |
Shipping Date: | 3-5 Working Days |
MODLE: | PN 705-0840 12V20W |
Storage temperature: | -20-70°c |
MOQ: | 1 PCS |
COLOR: | Metal and glass |
Delivery Date: | 3 - 5 Working Days |
Package | Carton |
The company has been professionally operating various brands of original medical monitoring instruments since 2015. The company has many professional senior engineers and has sufficient ability to undertake various medical equipment maintenance work. Covering motherboards, sensors, probes, modules, connectors, shells, etc. for various medical monitoring equipment.
We default to express delivery by DHL,Fedex, We will contact you as soon as possible when sending express delivery. If you have any questions after receiving the express delivery, please feel free to contact us at any time.