727-0536 Roche 12V 50W C311 C6000 C501 Biochemical Analyzer Luminous Lamp ROCHE12V50W
Roche 12V 50W incandescent lamp (model: 727-0536/C311/C6000/C501) biochemical analyzer bulb. When choosing to replace the bulb, different biochemical analyzer models may use bulbs with different interfaces. Please confirm the equipment manual or original label before replacement. Alternatively, you can seek confirmation from a professional engineering and maintenance technician before purchasing, so as not to waste your valuable time using the biochemical analyzer machine. It is best to purchase the same type of bulb produced by the original factory when choosing to replace the bulb. The bulb produced by the original factory can ensure that the light intensity and wavelength meet the testing standards.
Light bulb parameters:
Model: Roche 727-0536
Filament type: halogen lamp (incandescent lamp)
Replaceable bulb model: C311,C6000,C501
Voltage: 12V
Power: 50W
Lamp type: usually considered as GY6.35 dual socket
Suitable for: Roche/Hitachi production analyzers Cobas C311/C501/C6000, etc
Most light sources use halogen lamps with a working wavelength of 325-800nm. The service life of halogen lamps is relatively short, generally only 1000 to 1500 hours. Hitachi's light source lamp is a 12V20W halogen tungsten lamp (also known as a halogen lamp). The two words halogen tungsten represent the material used to make this light bulb. Halogen is the halogen gas, and the lamp bead is filled with halogen gas. Tungsten is the metallic tungsten, and the luminous filament is a tungsten wire.
When the luminous intensity of the lamp is insufficient, the instrument will automatically sound an alarm and should be replaced in a timely manner. The following are the three most common signs of poor lighting in the workplace. If the usage time is appropriate, it can be replaced manually. When installing a new light source lamp, be sure not to touch the bulb with your hands. If touched, it is recommended to use a dust-free fiber cloth or gauze dipped in alcohol to wipe it clean; When the motor of the biochemical analyzer stops, open the iron plate on both sides of the reaction cup, rotate the black rotating disk counterclockwise, and you will see the light bulb. Pinch the metal stopper and power cord on the right side with force, wait for 5 minutes until the light source is completely cooled down, and then unscrew the metal nut that fixes the light source to replace the light bulb.
Type: | 727-0536 Roche 12V 50W C311 C6000 C501 biochemische analysator gloei lamp ROCHE12V50W |
Warranty period: | 90 Days |
Shipping Date: | 3-5 Working Days |
MODLE: | 727-0536 Roche 12V 50W |
Storage temperature: | -20-70°c |
MOQ: | 1 PCS |
COLOR: | Metal and glass |
Delivery Date: | 3 - 5 Working Days |
Package | Carton |
The company has been professionally operating various brands of original medical monitoring instruments since 2015. The company has many professional senior engineers and has sufficient ability to undertake various medical equipment maintenance work. Covering motherboards, sensors, probes, modules, connectors, shells, etc. for various medical monitoring equipment.