Infrared Indicator Light Foot Massager PCBA Circuit Board With Charging Times
Specification
What determines whether the output power can be increased: |
Yes, by heating plate power, adapter power supply (battery output allowed) |
Input power |
5V2A |
Plasma |
35mA |
Extra parts |
FPC wiring |
Type of output driver:
(IC, MOS, SCR, relay, etc.)
|
MOS tube |
air pump valve |
less than 1A |
Infrared indicator light |
sterilization |
This current will vary with the pressure, and this current value is the maximum value under the actual test condition (the test condition was male mode 3, and the test result was massaged by the tester by hand, different people will have some deviation).
Parameter
The battery voltage |
Single air bag pressure protection
(Open a valve, the air pump will not open)
|
Double air bag pressure protection
(Open two valves, the air pump will not open)
|
Single air bag charging
(Open a valve and air pump)
|
Double air bag charging
(Open two valves and air pump)
|
4.2V(Full recharge) |
350ma |
630ma |
650-790ma |
950-1100ma |
3.3V(Low electricity) |
280ma |
510ma |
540-710ma |
830-900ma |
Operation
- Press the power button, the power indicator light, the first gear indicator light and the time indicator light for 15 minutes will be on. Air pump, valve 1 start to open the work, the foot air bag began to inflate. Display current charge (3 of 3 cells or one or two cells)
- Add 5 more lights (yellow, red, red, blue, green). When plasma is on, the breath flashes gradually.
- During the boot process,
- Press the force key, then first gear, second gear, third gear cycle,
- Press the time key, then 5 minutes, 10 minutes, 15 minutes cycle (backward time to turn off all output, standby).
- Press the fan, heating, anion and LED keys, and the corresponding indicator light and output are all on and off.
- All outputs (fan, heater, anion, LED, air pump, air valve) and batteries are connected to the power panel.
- Battery with 2600mAh*2.
- When starting to work, follow the football-> football-> football-> football-air bag at the same time as the football-> football-air bag. Each air bag is filled in three times, that is, filled with -> pressure-retaining -> pressure-retaining -> pressure-retaining -> pressure-retaining -> pressure-retaining -> deflating. As shown in the figure below.
We have:
- Professional technical and research department, providing strong technology strength
- Strict quality control team, 100% ensure the quality of products
- Excellent sales teams, sell our products to all over the world
- An energetic and productive marketing team
- Many outstanding logistic partners, ensure deliver in time