SME-350 MIL STD 2000A Ionic Contamination Tester PCBA contamination tester PCB contamination tester. It is specially used to accurate test the ions on the surface of PCBA,PCBA and semiconductor products.
SME-350 adpot ROSE method to check mix ions quantity to calculate Nacl Eq/cm2 value through its high precise probes and precise analysis system.
SME-350 will print the test result after testing.
Machine advantages:
1. Provide an accurate, repeatable, raped method for ionic contamination test.
2. Determine the cleanliness of bare PCB and assembly PCBA.
3. Comly with current industrial specifications such as IPC-TM-650, MIL-STD-2000A,MIL-P-28809,DEF-STD-10/03,IEC...
4. Test tank specially designed for complete ionic contamination extraction.
5. Test tank changable, tank can be made on customer's request.
6. More reasonable control mechanism to ensure accurate test.
7. Dynamic or Static test method.
8. Easy-use software, friendly interface, English/Chinese language.
Test Software: Power CTM
1. Windows work environment( windows7, windows xp,etc).
2. English/Chinese interface.
3. USB communication port.
4. Word or PDF report form.
5. Metric(cm)/Britsh(inch) system.
6. Simple parameters set-up.
7. Chart, data, status on one screen.
SME-350 SPEC
Item | SME-350 | Remarks |
Test method | Dynamic | |
Level adjustment | Yes | |
Sensitiveity | 0.001us/cm | |
Solution capacity(L) | 15 | |
Tank size(mm) | 500x500x45 | |
Sample size(mm) | 480x400x45 | |
Heater | Yes | |
Max operation temp(ºC) | 45 | |
Power supply | AC220V,50Hz, 1A | |
Machine size(mm) | 900x435x1100 | |
Weight | 85 |
Q1: Is this machine precise enough?
A1: Yes, we use sensor 0.001us/cm, so don't worry about it.
Q2: What standard can this tester meet?
A2: All kinds of international standard, like: MIL-P-28809, MIL-STD-2000A, DEF-STD-10/03...