NBC
DPDT DC12V 16A PCB Mount Relay GP-12VDC-2C54 for Smart Sweeper
Description:
GP series PCB mount relay,high density,multiple contact form to option,1A,1C,2A,2C,maximum load current is 16A,can meet different requirements of users.
Feature:
1. Coil voltage can be 5V/6V/9V/12V/24V/48V
2. 0.54W or 0.72W for coil power
Application:
1. Appliances
2. Instrument
Specification:
Contact Form | 1A, 1C,2A, 2C | |
Contact Material | AgSnO2 AgCdO | |
Contact Rating (Resistive) | 1A1C: 16A/250VAC, 30VDC 2A2C: 8A/250VAC,30VDC | |
Switching Power Max. | 480W 4000VA | |
Switching Voltage Max. | 30VDC 250VAC | |
Switching Current Max. | 16A | |
Contact Resistance | ≤ lOOmQ | |
Endurance | Electrical | 105 |
Mechanical | 107 |
Technical Rating
Insulation Resistance | 100MQ(500VDC)Min. | Item 7 of IEC 255-5 | |
Dielectric Strength | Between Open Contacts | 1000VAC 50Hz | Item 5 of IEC 255-5 |
Between Contact and Coil | 2500VAC | Item 6 of IEC 255-5 | |
Shock Resistance | 100m/s2 | IEC 68-2-27 Test Ea | |
Vibration Resistance | 10Hz ~ 50Hz double amplitude 1.5mm | ||
Leading-out Terminal Strength | 10N | ||
Ambient Temperature | -40°C ~ 85°C | ||
Relative Humidity | 85% (at40°C ) | ||
Weight | 13g |
Coil Rating
Coil Voltage(VDC) | Coil Resistance R(1 ± 10%)Q
| PickupMax.(VDC) (75% of Nominal Voltage) | Drop out Min.(VDC) (10% of Nominal Voltage) | Coil Power (W) 0.54/0.72 | Operate Time(ms) 15 | Release Time (ms) 5 | |
Nominal | Max. | ||||||
5 | 6.5 | 47/36 | 4.0 | 0.25 | |||
6 | 7.8 | 68/50 | 4.8 | 0.30 | |||
9 | 11.7 | 155/115 | 7.2 | 0.45 | |||
12 | 15.6 | 270/200 | 9.6 | 0.60 | |||
24 | 31.2 | 1100/820 | 19.2 | 1.2 | |||
48 | 62.4 | 4400/3300 | 38.4 | 2.4 |
3 Measurement and circuit of 16a 12v relay
![]() |
Outline Dimensions |
![]() |
Bottom View PCB Layout |
![]() |
Wiring Diagram ( Bottom View) |
![]() |
Engineering Data |