WRG Relay 20A Power Relay RMIF-112LM Safety Protection Miniature
20A Power Relay Description:
RMIF series power relay, rated current from 16A to 20A,5KV dielectric withstand between coil and contact, multiple mounting, like standard type with PCB mount and quick terminal 187, instead of, removing M and C QT, removing terminal M and C PCB pin, removing terminal C PCB pin, removing terminal M PCB pin, removing terminal M and C PCB pin, and adding dummy terminal. It has enough insulation distance for the control switch, safety standard 60335-1 available, especially use for home appliances.
20A Power Relay Features:
1. 1 form A,16A to 20A rated current
2. flux-resistance or sealed
3. enough insulation distance between coil and contact
4. quick terminal 187
20A Power Relay Specification:
General data | |||||||||
Rated withstand impulse voltage | coil contact | 5kV AC/1min | |||||||
between contact | 1kV AC/1min | ||||||||
Surge voltage | 10kV AC(1.2/50μs) | ||||||||
Insulation resistance | 1000MΩ(500VDC) | ||||||||
Vibration | Fault 10-55Hz(amplitude 1.5mm) | ||||||||
Endurance 10-55Hz(amplitude 1.5mm) | |||||||||
Shock | Fault 98m/S2 ,Endurance 980 m/s2 | ||||||||
Operating temperature | -40 ~ 105℃(no condensation) | ||||||||
Operating humidity | 20 ~ 85% | ||||||||
Dimension LxWxH(mm) | 29.0x12.6x24.4 | ||||||||
Enclosure type | Flux-resistance | ||||||||
Mounting | PCB | ||||||||
Weight(g) | 15 | ||||||||
Certifications | cULus:E345228/TUV:R50227054 |
20A Power Relay Introduce:
New electromagnetic relays include non-magnetic latching relays and magnetic latching relays. The non-magnetic latching relay is a monostable relay. The relay coil is under the action of the specified voltage excitation, and its contact output state changes, but after the coil excitation is withdrawn, the contact output state returns to the initial state. A magnetic latching relay is a kind of bistable relay, which is divided into a single-coil structure and a double-coil structure, and the coil is excited by an electric pulse. For single-coil structure relays, when the coil is under the action of the specified voltage excitation, the contact output state changes, and the contact can maintain the existing state after the coil excitation is canceled. To change the contact output state, it is necessary to add a specified voltage to the coil. Amount of reverse voltage excitation. For a double-coil structure relay, when the first coil is under the action of the specified voltage excitation, the contact output state changes. After the coil excitation is canceled, the contact can maintain the existing state. To change the contact output state, the second contact output state needs to be changed. The coil is excited by the specified voltage.