Specifications
Brand Name :
SYSEYE
Model Number :
ST-1000
Certification :
TUV
Place of Origin :
China
MOQ :
1
Price :
$6,500.00-$7,900.00
Payment Terms :
T/T
Supply Ability :
100
Delivery Time :
5 working days
Packaging Details :
380 mm (L) x 460mm (W) x 505mm (H)
Product name :
Automatic Tonometer
Size :
380 mm (L) x 460mm (W) x 505mm (H)
Weight :
19.7kg
Power supply :
220V/50HZ
Working distance :
≥11mm
R/L :
automatic detection and display
Recording :
build-in printer
feature :
Assisting In The Diagnosis Of Cataract Glaucoma
Description

Assisting In The Diagnosis Of Cataract Glaucoma Automatic Tonometer

Automatic Tonometer measurement, also known as pneumatic intraocular pressure measurement, is a method of measuring intraocular pressure without direct contact with the eyeball. In the examination, the gas pulsed force in the instrument flattens a specific area of the cornea center, and the relationship between the force required and the intraocular pressure is used to calculate the intraocular pressure examination method. The gas impulse force has a linear increasing relationship with the duration of the impulse, and the intraocular pressure value is indirectly converted by the duration of the impulse force. This measurement method is simple, fast and basically correct.

Automatic Tonometer utilizes image control and feature recognition for auto 3-D positioning of xyz with reliable judgment and measurement results, and easy to operate. The air non-contact approach to measure IOP can also be used for corneal thickness (ST-1000P).

Product Description Of Automatic Tonometer

Screen color and touch,

Rotating screen like Topcon.

Motorized chinrest

Auto tracking eye , you can select auto or manual .

if select auto , will automatic adjust the chinrest distance , height, and shoot air to measure . two second finish .

Intraocular pressure (IOP) measuring range: 1mmHg~ 30mmHg /1mmHg ~60mmHg ( precision of 1mmHg)
Measuring system: dual sensor system of light and pressure
Working distance:≥11mm
R/L: automatic detection and display
Measuring result: 10 times per eye; 3 times result printing per eye
Recording: build-in printer
Measuring mode: auto/manual
Focus: when luminous spot is in the focus frame, 2 modes can be chosen.
Auto mode: auto intraocular pressure measurement
Manual mode: when it's good focus, the frame will turn yellow into green, and click to start the measurement
Error indication: if the measurement signal is weak, the IOP will be enclosed by ( ), or display “ERR ”
Safety limit button: install measurement for minimum distance between head and patient
Safety functions: the distance between air nozzle and cornea is controlled in preset range(such as 11mm); it will stop going forward when the cornea is too closed to air head.
Movement range:≥30mm(front to back)/ 90mm(left to right)/ 30mm(vertical)
Jaw layer vertical movement: 0~65mm with under jaw layer
Display mode: 10.1-inch HDMI color LED touch monitor
Output port: USB2.0
Working platform: electric elevating platform


Automatic Tonometer specification

Intraocular pressure (IOP) measuring range 1mmHg~ 30mmHg /1mmHg ~60mmHg ( precision of 1mmHg)
Measuring system dual sensor system of light and pressure
Working distance ≥11mm
R/L automatic detection and display
Measuring result 10 times per eye; 3 times result printing per eye
Recording build-in printer
Measuring mode auto/manual
Movement range ≥30mm(front to back)/ 90mm(left to right)/ 30mm(vertical)
Jaw layer vertical movement ≥30mm(front to back)/ 90mm(left to right)/ 30mm(vertical)
Display mode 10.1-inch HDMI color LED touch monitor
Output port USB2.0


Pneumatic Automatic Tonometer TUV For Cataract Glaucoma Diagnosis
Pneumatic Automatic Tonometer TUV For Cataract Glaucoma Diagnosis

Company Introduction

Pneumatic Automatic Tonometer TUV For Cataract Glaucoma Diagnosis

Focusing on the two major public health problems of adolescent myopia and elderly ophthalmology, our company researches new diagnostic and treatment equipment for ophthalmology, develops low-cost applicable technology products, realizes industrialization, reduces the cost of social medical and health system, and serves the strategic needs of national health.The company always adhere to the "high-tech,new vision" for the enterprise development concept.We have a strong technical force, has been awarded 11 patents, and obtained 13,485 quality system certification.Bio has established an efficient marketing team and a perfect after-sales service system to provide medical equipment with the highest cost performance and meticulous service.

Pneumatic Automatic Tonometer TUV For Cataract Glaucoma Diagnosis

Send your message to this supplier
Send Now

Pneumatic Automatic Tonometer TUV For Cataract Glaucoma Diagnosis

Ask Latest Price
Brand Name :
SYSEYE
Model Number :
ST-1000
Certification :
TUV
Place of Origin :
China
MOQ :
1
Price :
$6,500.00-$7,900.00
Contact Supplier
Pneumatic Automatic Tonometer TUV For Cataract Glaucoma Diagnosis
Pneumatic Automatic Tonometer TUV For Cataract Glaucoma Diagnosis

Chongqing Bio Newvision Medical Equipment Ltd.

Verified Supplier
4 Years
chongqing, chongqing
Since 2011
Business Type :
Manufacturer
Total Annual :
20000000-30000000
Employee Number :
200~500
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement