20rpm-3000rpm SKF bearing permanent magnet alternator
Permanent magnet alternator
Permanent magnet alternators are usually used to generate electricity. The automotive alternator converted to permanent magnet type is used for household wind generators, hydroelectric power generation and self-made backup generators. Common automotive alternators use electromagnet-driven rotors to turn the alternator on and off. Permanent magnet alternators have permanent magnets instead of rotor cores wound by electromagnetic wires.
The reason why cars use an electromagnetic rotor core is because they can use it to control the output of the alternator. The use of a voltage regulator can control the voltage sent to the electromagnetic rotor core. With a permanent magnet alternator, you will not be able to control the output of the alternator, because it does not have a voltage stabilizer or solenoid winding core to control the alternator.
The control of a permanent magnet alternator is usually done by changing the speed of the alternator. With a permanent magnet alternator, the faster the alternator rotates, the more power the alternator generates.
What are the advantages of permanent magnet alternators in wind energy applications?
Direct drive (no speed increaser, no gearbox required)
No maintenance
Highest power-to-weight ratio in direct drive
high efficiency
Simplify mechanical design
Simple mechanical interface
Cost optimization
Wind turbines are usually equipped with asynchronous generators that need to double the speed of the rotor in order to generate the desired electrical power. Compared with asynchronous generators, permanent magnet alternators are very compact, and because the rotor is directly driven, mechanical integration can be simplified. The efficiency of permanent magnet synchronous alternators is higher than that of asynchronous generators.
The application of wind turbines is growing-the cost of generating 1 kW per hour of wind energy is the cheapest renewable energy source
Technical Data
Features of 50kw permanent magnet generator
Low startup speed;
Low torque
Gearless, direct drive, low-speed generator.
Suitable for all environments
Excellent heat dissipation
High-quality bearings and magnets are easy to dissipate heat and maintain magnetism.
The designed service life is 20 years.
RATED POWER | RATED SPEED | RATED VOLTAGE | FREQUENCY |
0.5KW | 20rpm~400rpm | 12V~220Vac | 10Hz~60Hz |
1KW | 20rpm~600rpm | 12V~220Vac | 10Hz~60Hz |
2KW | 20rpm~1000rpm | 12V~400Vac | 10Hz~60Hz |
3KW | 20rpm~1500rpm | 48V~690Vac | 10Hz~60Hz |
5KW | 20rpm~1500rpm | 48V~690Vac | 10Hz~60Hz |
10KW | 20rpm~1500rpm | 120V~690Vac | 10Hz~60Hz |
15KW | 20rpm~3000rpm | 120V~690Vac | 10Hz~60Hz |
20KW | 20rpm~3000rpm | 120V~690Vac | 10Hz~60Hz |
25KW | 20rpm~3000rpm | 120V~1140Vac | 10Hz~60Hz |
30KW | 20rpm~3000rpm | 120V~1140Vac | 10Hz~60Hz |
50KW | 20rpm~3000rpm | 220V~1140Vac | 10Hz~60Hz |
80KW | 20rpm~3000rpm | 220V~1140Vac | 10Hz~60Hz |
100KW | 20rpm~3000rpm | 220V~1140Vac | 10Hz~60Hz |
150KW | 20rpm~3000rpm | 380V~1140Vac | 10Hz~60Hz |
200KW | 20rpm~3000rpm | 380V~1140Vac | 10Hz~60Hz |
250KW | 20rpm~3000rpm | 380V~1140Vac | 10Hz~60Hz |
300KW | 20rpm~3000rpm | 380V~1140Vac | 10Hz~60Hz |
500KW | 20rpm~3000rpm | 380V~1140Vac | 10Hz~60Hz |
700KW | 20rpm~3000rpm | 690V~1140Vac | 10Hz~60Hz |
800KW | 20rpm~3000rpm | 690V~1140Vac | 10Hz~60Hz |
1MW | 200rpm~3000rpm | 690V~1140Vac | 10Hz~60Hz |
2MW | 200rpm~3000rpm | 690V~1140Vac | 10Hz~60Hz |
3MW | 200rpm~3000rpm | 690V~1140Vac | 10Hz~60Hz |
4MW | 600rpm~3000rpm | 690V~1140Vac | 10Hz~60Hz |
5MW | 600rpm~3000rpm | 690V~1140Vac | 10Hz~60Hz |