Grid-Tied Controller is technologically the most important component in wind generator on-grid systems, which convert Three AC current from wind turbine into DC current then send to the grid-tie invertor. GT-PCTC series wind professional grid-tied controller which have Double safety control systems:PWM constant voltage system and three-phase dump load brake system, It can control Solis solar invertor working then let the solar invertor suitable for wind turbine working condition.
Product Parameters
Type
GT-PCTC-1.5KW
GT-PCTC-2KW
GT-PCTC-3KW
GT-PCTC-5KW
Wind turbine rated power
1.5KW
2KW
3KW
5KW
Wind turbine rated voltage
AC220V-240V
AC220V-240V
AC220V-380V
AC380-450V
Function
Rectifier,Control,DC output
Automatic protection function
Over voltage protection, Grid cut off protection, Regulated supply output, Arrester
Manual function
Manual brake, Reset, Emergency switch
Display mode
LCD Touch Screen
Display content (larger one)
Generator speed(rpm),Input voltage (Vdc), Input current(Vac) ,Output power(kW), Grid voltage (Vac),Grid current(A), Power generate today(kWh),Power generate this month, Power generate last month, Power generate this year, Power generate last year,Power Curve setting.
3-phase dump load time-lapse
12-20 min
12-20 min
12-20 min
12-20 min
Wind turbine 3-phase dump load voltage
450±5Vdc
750±5Vdc
PWM constant voltage
≥400dc
≥700dc
Environment temperature
-30-60°C
Relative humidity
<90% No condensation
Noise (1m)
<40dB
Degree of protection
IP20(Indoor) IP65 (Outdoors)
Cooling method
Forced air cooling
Communication interface (optional)
RS485/USB/GPRS/WIFI/Ethernet
Type
GT-PCTC-10KW
GT-PCTC-20KW
GT-PCTC-30KW
Wind turbine rated power
10KW
20KW
30KW
Wind turbine rated voltage
AC380-520V
Function
Rectifier,Control,DC output
Automatic protection function
Over voltage protection, Grid cut off protection, Regulated supply output, Arrester
Manual function
Manual brake, Reset, Emergency switch
Display mode
LCD Touch Screen
Display content (larger one)
Generator speed(rpm),Input voltage (Vdc), Input current(Vac) ,Output power(kW), Grid voltage (Vac),Grid current(A), Power generate today(kWh),Power generate this month, Power generate last month, Power generate this year, Power generate last year,Power
Curve setting.
PWM constant voltage
≥700dc
Wind turbine 3-phase dump load voltage
750±5Vdc
Wind turbine 3-phase dump load time-lapse
12-20 min
Environment temperature
-30-60°C
Relative humidity
<90% No condensation
Noise (1m)
<40dB
Degree of protection
IP20(Indoor) IP65 (Outdoors)
Cooling method
Forced air cooling
Communication interface (optional)
RS485/USB/GPRS/WIFI/Ethernet
Product Details
System Solution
Greef has a professional team to create a tailor-made system for customers, this picture is an example, if you have other requirements, please contact us!
Product packaging
Why Choose Us
Product tags
Send your message to this supplier
Send Now
Submission successful!
3kw 5kw 10kw GT-PCTC Series Wind Turbine On Grid Controller With Inverter For System