Product Name :Automatic Control Pharmaceutical Water Treatment Plant Full Stainless Steel Material
CHONGYANG WATER Plant Introduction
Purified water preparation system can affect pharmaceutical water directly,
it submits to GMP critical system.
RO and EDI equipment are designed for application in a wide range of purified water preparation of pharmaceutical plant and core equipment.
Reverse osmosis is also called opposite osmosis relative to “osmosis”.
Osmosis is a process of water from the dilute solution flows to concentrate through the semi permeable membrane automatically.
For the reverse osmosis, in the action of applied pressure, water from the concentrate flows to the dilute solution, it is un-optional.
EDI is also called continuous electro deionization, it brings electro dialysis and ion exchange technology together as one, By the action of electric field, ion directional movement then removes the salts. The working of EDI also a process of resin rebirth continuously, EDI device is after RO system.
CHONGYANG WATER Spec. & Type :
TYPE | Capacity (M3/H) | Pipe DN (mm) | WP (MPa) | Material | Work Method |
CY-PW-0.25 | 0.25 | DN20 | ≤1.0 | Stainless Steel/Carbon Steel | Full Automatic/Semi-Automatic |
CY-PW-0.5 | 0.5 | DN20 | ≤1.0 | Stainless Steel/Carbon Steel | Full Automatic/Semi-Automatic |
CY-PW-1 | 1 | DN25 | ≤1.0 | Stainless Steel/Carbon Steel | Full Automatic/Semi-Automatic |
CY-PW-2 | 2 | DN32 | ≤1.0 | Stainless Steel/Carbon Steel | Full Automatic/Semi-Automatic |
CY-PW-3 | 3 | DN40 | ≤1.0 | Stainless Steel/Carbon Steel | Full Automatic/Semi-Automatic |
CY-PW-5 | 5 | DN50 | ≤1.0 | Stainless Steel/Carbon Steel | Full Automatic/Semi-Automatic |
CY-PW-10 | 10 | DN75 | ≤1.0 | Stainless Steel/Carbon Steel | Full Automatic/Semi-Automatic |
CY-PW-20 | 20 | DN100 | ≤1.6 | Stainless Steel/Carbon Steel | Full Automatic/Semi-Automatic |
CY-PW-30 | 30 | DN125 | ≤1.6 | Stainless Steel/Carbon Steel | Full Automatic/Semi-Automatic |
CY-PW-40 | 40 | DN150 | ≤1.6 | Stainless Steel/Carbon Steel | Full Automatic/Semi-Automatic |
CY-PW-50 | 50 | DN200 | ≤1.6 | Stainless Steel/Carbon Steel | Full Automatic/Semi-Automatic |
1st RO Water Conductivity | ≤10.0μS/cm (25℃) | 2nd RO Water Conductivity | ≤3.0μS/cm (25℃) |
EDI Water Conductivity | ≤0.1μS/cm (25℃) | TOC | ≤ 0.5mg/l |
Disinfection for loop | Pasteurization | Disinfection for Activated carbon | Pasteurization |
Microbial limit | ≤ 50 CFU/100ml | ||
FAQ:
1. Questions :Is the circulating system important for Pharma Water System ?
Answer : Sure . Circulating system design is an important for purified water system .A one-way system is basically a "dead-leg " .
2. Questions : Can the purified water system be used for cosmetic industry ?
Answer : With improvement of living conditions, The high level cosmetic series need to pharma class water treatment system .
3.Questions: Do there need diaphragm valve on sampling water place ?
Answer:Sure .