Specifications
Brand Name :
Daruifuno
Model Number :
DUC2-EC-H-A
Certification :
CE, ISO
Place of Origin :
China
MOQ :
1
Payment Terms :
T/T, Western Union, MoneyGram
Supply Ability :
10000 Sets per Month
Delivery Time :
5-25 days
Packaging Details :
Carton
Product Name :
Conductivity Controller
Conductivity Display :
0.000µS /cm ~500mS/cm
Resistivity Display :
0.01Ω.cm~18MΩ.cm
TDS Display :
0.000mg/L~500g/L
Salinity Display :
(0.00~10.0)%
Temp Display :
-10~500℃ /14~932℉
Relay Control :
2 settable SPST relays
Analog output :
2 settable 0/4~20mA
Communication :
Two-wire RS485 interface;
Data Record :
14000 historical data
Description

Digital 100~240VAC Conductivity/TDS Controller For Drinking Water Monitoring

Digital Conductivity/TDS Analyzer:This set of digital Conductivity/TDS analyzer can detect conductivity, resistivity, salinity, TDS and temperature in water.

Specification:

Model DUC2-EC-H-A
Software Version DRFN EC Analysis software V1.0
Sensor Input Compatible with all DRFN's EC Digital Sensors
Display Range Conductivity 0.000µS /cm ~500mS/cm
Resistivity 0.01Ω.cm~18MΩ.cm
TDS 0.000mg/L~500g/L
Salinity (0.00~10.0)%
Temp -10~500℃ /14~932℉
Resolution Conductivity 0.001µS /cm
Resistivity 0.01Ω.cm
TDS 0.001mg/L
Salinity 0.01%
Temp 0.1℃/ 0.1℉
Relay Control 2 settable SPST relays with a maximum load of 3A/250VAC
Analog Current Output 2 settable 0/4~20mA current outputs, max. load 1000Ω
Communication Method

Two-wire RS485 interface

MODBUS RTU

support JSON text data format

OTA ——
Display Screen 128*64 LCD, adjustable backlight mode, adjustable display rate
Configuration Information Power off protection, parameters are retained indefinitely
Time /Data Record

Year/month/day/hour/min/second, record 14000 historical data

record interval can be set between 1~999 minutes

Maintenance Records Last 100 times
Operating Environment 0~60℃,RH<95% ( no condensation)
Storage Environment -20~70℃,RH<55% ( no condensation, precision instruments)
Shell Material Enhanced ABS
Protection Grade IP66
Dimension 144*144*120 mm
Mounting Method Wall mounting, pipe clamping, panel installation (hole size 138*138 mm)
Electrical Interface The back end reserved 3 M12*1.5 Gram head, line diameter 3~6.5 mm
Power Supply 100~240VAC
Power Consumption About 7W
Weight About 800g

Please click the catalog of RS485 EC controller here:

Daruifuno Catalog.pdf

Brief introduction:
● Compatible with all DRFN conductivity sensors;
● Separately have a list of controller and sensor settings for quick and detailed parameter setting;
● The working status of the sensor can be queried, including reading the serial number;
● Support a variety of installation methods;
● Time and historical data recording function;
● 3.2-inch large LCD screen;
● User-friendly Chinese and English language interface;
● Password can be set to prevent misoperation;
● 2 SPST multi-function and settable relays;
● Two 0/4~20mA active current loop outputs;
● RS485 interface, Modbus RTU communication protocol;
● IP66 waterproof level, sealed enclosure can isolate pollution and corrosive gas;
● OTA download technology as a smart configuration option for the instrument.

Digital 100~240VAC Conductivity/TDS Controller For Drinking Water Monitoring

Aplication:
◇ Drinking water
◇ Pure water
◇ Cooling water
◇ Sewage
◇ Industrial process water


FAQ


Q1. What are the special advantages of the pH instruments?
A: The instrument can not only compensate the temperature of the test sample by connecting the temperature sensor, but also self-check the working temperature of the instrument in real time. When the working temperature of the instrument changes, the instrument compensates the hardware change caused by the temperature drift. Make the test results more accurate, this is a patented technology.

Q2. Does the operation interface support customization?
Yes, our operation interface can be tailored to customers' needs.

Q3.Can our company's logo be added to your company's products?
Of course, we support OEM services for customers.

Q4.How long is the warranty period?
The company guarantees the instrument for one year (12 months) from the date of leaving the factory, and the consumables and wearing parts in the equipment are not covered by the warranty.

Send your message to this supplier
Send Now

Digital 100~240VAC Conductivity/TDS Controller For Drinking Water Monitoring

Ask Latest Price
Brand Name :
Daruifuno
Model Number :
DUC2-EC-H-A
Certification :
CE, ISO
Place of Origin :
China
MOQ :
1
Payment Terms :
T/T, Western Union, MoneyGram
Contact Supplier
Digital 100~240VAC Conductivity/TDS Controller For Drinking Water Monitoring
Digital 100~240VAC Conductivity/TDS Controller For Drinking Water Monitoring
Digital 100~240VAC Conductivity/TDS Controller For Drinking Water Monitoring

Suzhou Delfino Environmental Technology Co., Ltd.

Verified Supplier
5 Years
jiangsu, suzhou
Since 2015
Business Type :
Manufacturer, Exporter, Seller
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement