Specifications
Brand Name :
Daruifuno
Model Number :
ASP300-TYD05
Certification :
CE
Place of Origin :
China
MOQ :
1
Price :
Negotiable
Payment Terms :
T/T, Western Union, MoneyGram
Supply Ability :
10000 Sets per Month
Delivery Time :
5-15 days
Packaging Details :
Carton
Product Name :
PH sensor
Item :
ASP300-TYD05
PH :
0~14pH 0.01pH
Shaft Material :
ABS+Glass+g
Working Temperature :
0.0~60.0℃
Reference System :
Double salt bridge
Reference Electrode :
Ag/AgCl
Working Pressure: :
0~2Bar
Temperature compensation :
PT1000
Cleaning :
Cleaning interface (Optional)
Description

Side Wall Installation PH Sensor With PT1000 /PT100 Temp. Compensation

The pH value is related to temperature, and the pH electrode gives a measurement result determined by the temperature. So the temperature needs to be recorded and temperature compensated.

Our pH sensor ASP300-TYD05 comes with a PT1000/PT100 temperature compensation unit that can compensate for temperature.


pH electrodes need to be calibrated regularly. It is most appropriate to calibrate at least once a day. After calibration, the slope and zero of the electrode can be determined.


To get correct measurement results, it is essential to calibrate the slope and zero of the electrodes. A calibration curve correlates the mV value measured by the electrode to the pH of the solution.

Since each electrode has its characteristic zero point and slope, a minimum two-point calibration is essential for reliable and accurate results. When measuring a wide range of pH values, at least a 3-point calibration is required.

If a temperature probe is not used, make sure to calibrate and measure at the same temperature. Manual temperature entry is required in this case, allowing the meter to correct for the buffer temperature.

Specification:

Modle

ASP300-TYD05
PH Range
0~14pH 0.01pH
Shaft Material
ABS
Working TEMP
0~60℃
Reference System
double salt bridge
Reference Electrode
Ag/AgCl
Electrolyte
Solid Gel
Working Pressure
0~2Bar
Operating Temperature
0~60℃
Working Pressure
0~2Bar
Temperature Unit
Vacant/NTC10K /PT1000 (optional)
Membrane
Porous

Glass Head

Transparent low impedance

Dimension
Diameter: 35mm Length: 260 mm ( include the cleaning cover)
Thread Size
1 inch NTP(both ends)
Lead Wire
Standard 5m
Ground
--
Cleaning
A protective cover with its own cleaning interface(Optional)
Application
Industrial water

Please click the user manual of pH sensor here:

PH sensor User Manual.pdf

Brief introduction:

◆ pH composite electrode, the body adopts reinforced ABS plastic shell encapsulation, the structure is firm, there are installation threads at the beginning and the end, and the installation is convenient;


◆ The electrode is equipped with a protective cover with its own cleaning interface, and the user can quickly access the automatic cleaning system;


◆ The electrode is divided into 3 basic models according to the packaging method of the temperature unit;
◆ The indicator electrode adopts a low-impedance hemispherical glass head, which has high strength and is not easily broken;


◆ The reference adopts a large-area annular porous membrane, which has fast penetration speed, fast response, not easy to block, and easy to clean;


◆ The reference system is designed with double salt bridge, the reference electrode is Ag/AgCl, filled with KCL solid gel.

◆ Power supply mode: AC power supply 100~240VAC and DC power supply 18~36VDC.

Side Wall Installation PH Sensor With PT1000 / PT100 Temp. Compensation

Aplication:

Water treatment monitoring

Drinking water,surface water,water quality analyze,ground water,ect.

Industrial process monitoring and dosing control

Chemical,petroleum,paper,food and medicine,PCB manufacturing,etc.

FAQ

1. What is themeasurement principle of this pH electrode?
A: The pH value potentiometric method uses the potential difference of glass electrodes for pH measurement.


2. How is this glass pH electrode composed?
A:
The pH electrode is usually composed of an indicator electrode and a reference electrode.


3. How to judge the pH of the solution?
A:
If the internal hydrogen ion concentration of the pH glass bulb is lower than the outside, the measured solution is recorded as acidic and the pH value is lower than 7; if the two are the same, the solution is neutral and the pH value is equal to 7; if the internal hydrogen ion concentration is higher than externally, the measured solution is alkaline and the pH value is higher than 7.


4. What is the wire length of the pH electrode?
A:
The lead wire of this electrode is 5m by default, other lengths need to be customized, contact our customer service, the price will vary with the change of length.

5. How often must the pH sensor be calibrated?
A: Depends on the type of sample: Dirty samples and non-aqueous samples require more frequent calibration. Depends on the required accuracy: For very accurate measurements, at least daily calibration is required. Depends on the quality of the electrode: Old electrodes require more frequent calibration.

Send your message to this supplier
Send Now

Side Wall Installation PH Sensor With PT1000 / PT100 Temp. Compensation

Ask Latest Price
Watch Video
Brand Name :
Daruifuno
Model Number :
ASP300-TYD05
Certification :
CE
Place of Origin :
China
MOQ :
1
Price :
Negotiable
Contact Supplier
video
Side Wall Installation PH Sensor With PT1000 / PT100 Temp. Compensation
Side Wall Installation PH Sensor With PT1000 / PT100 Temp. Compensation
Side Wall Installation PH Sensor With PT1000 / PT100 Temp. Compensation

Suzhou Delfino Environmental Technology Co., Ltd.

Verified Supplier
5 Years
jiangsu, suzhou
Since 2015
Business Type :
Manufacturer, Exporter, Seller
Certification Level :
Verified Supplier
Contact Supplier