Specifications
Brand Name :
Daruifuno
Model Number :
WP10
Certification :
CE, ISO
Place of Origin :
China
MOQ :
Negotiable
Price :
Negotiable
Payment Terms :
T/T
Delivery Time :
1-45 work days
Packaging Details :
Carton
Product Name :
Hydrogen peroxide sensor
Product Model :
WP10
Measuring range: :
0~200/2000/20000 ppm
Pressure Range :
0 ~ 5 (Flow cell)
Temperature Range :
0 ~ 40 ℃
Response Time :
T90: approx. 8 min
Flow Rate :
15-30 l/h (33 – 66 cm/s)
Description

Chemicals High Tolerance Two-Electrode System Hydrogen Peroxide Sensor For All Water Treatment

The two-electrode system membrane hydrogen peroxide sensor WP10 has the following features and advantages, making it an excellent performer in the field of water treatment:

Features


Mechanically strong membrane system

The sensor adopts a high-strength membrane system design, which can operate stably in harsh environments and effectively prevent damage.


Surfactant tolerance

It has high tolerance to surfactants (such as detergents or chemical reagents) and is suitable for a variety of water quality conditions.


High tolerance to chemicals

It can resist the influence of a variety of chemicals (including strong oxidants or other corrosive substances) to ensure long-term stability.


Applicable temperature range

The working water temperature can reach up to 45℃, which meets most industrial water treatment needs.


Multiple optional ranges

Three ranges are available: 0200 ppm, 02000 ppm, and 0~20000 ppm, which meet different needs from trace detection to high concentration detection.


Advantages


Accurate measurement

Using a two-electrode system, it has high sensitivity and accuracy and can quickly respond to changes in hydrogen peroxide concentration.
Low maintenance requirements

Durable design and stable operation reduce maintenance frequency and cost.


Widely used

Applicable to various water treatment processes, including drinking water, industrial wastewater, sewage and circulating cooling water.


Easy to operate

Modular design and user-friendly interface for easy installation and use.


High stability

Not affected by water flow fluctuations, capable of long-term continuous operation, reducing the risk of instrument drift and data errors.

Two-electrode system, used in all water treatment, mechanically strong membrane system, resistant to surfactants, high resistance to chemicals, maximum water temperature: 45°C, optional range 0~200/2000/20000 ppm​

Chemicals High Tolerance Two-Electrode System Hydrogen Peroxide Sensor For All Water Treatment

Specifications

Chemicals High Tolerance Two-Electrode System Hydrogen Peroxide Sensor For All Water Treatment

WP10

Indicator Hydrogen peroxide

Application

All kinds of water treatment, also sea water, especially for high H2O2- concentrations.

The membrane system is mechanical resistant.

The membrane system is highly resistant to surfactants (tensides).

Measuring system Membrane covered, amperometric 2-electrode system.

Electronic

Analog version: - voltage output

- not galvanically isolated electronics

- analog internal data processing

- output signal: analog (analog-out/analog)

Digital version: - electronic is completely galvanically isolated

- digital internal data processing

- output signal: analog (analog-out/digital)

or

digital (digital-out/digital)

mA-version: - current output analog

- not galvanically isolated electronics

- output signal: analog (analog-out/analog)

Information about the measuring range

The actual slope of a sensor can vary production-related between 65% and 150% of the nominal slope

Note: With a slope > 100% the measuring range is reduced accordingly.

(Ex.: 150% slope → 67% of the specified measuring range)

Working temperature

Measuring water temperature: 0 … +45 °C

(no ice crystals in the measuring water)

Ambient temperature: 0 … +55 °C

Temperature compensation

Automatically, by an integrated temperature sensor Response time t90 = approx. 8 min.

Max. change in temperature: 5 °C per hour, sudden temperature changes must be avoided

Max. allowed working pressure

Operation without retaining ring:

- 0.5 bar

- no pressure impulses and/or vibrations

Operation with retaining ring in flow cell:

- 1.0 bar,

- no pressure impulses and/or vibrations

(see option 1)

Flow rate

(Incoming flow velocity)

Approx. 15-30 l/h (33 – 66 cm/s) in flow cell, small flow rate dependence is given
pH-range pH 2 – pH 11

Chemicals High Tolerance Two-Electrode System Hydrogen Peroxide Sensor For All Water Treatment

WP10

Run-in time First start-up approx. 5 h
Response time T90: approx. 8 min.

Accuracy

after calibration at repeatability conditions (25°C, pH 7.2 in drinking water) of the upper full scale

- Measuring range 200 ppm: at 40 ppm <2%

at 160 ppm <2%

- Measuring range 2000 ppm: at 400 ppm <0,5%

at 1600 ppm <2%

Zero point adjustment Not necessary
calibration At the device, by analytical determination

interferences

Cl2: must not be present

PAA: must not be present

O3: must not be present

Sulfides: contaminate the measuring system

Phenol: aqueous solution >3 % phenol, destroys the membrane system

Absence of the disinfectant Max. 24 h

Connection

mV version: 5-pole M12, plug-on flange

Modbus version: 5-pole M12, plug-on flange

4-20 mA version: 2-pole terminal

or

5-pole M12, plug-on flange

Max. length of sensor cable (depending on internal signal processing) Analog < 30 m
Digital

> 30 m are permissible

Maximum cable length depends on application

Protection type

5-pole M12 plug-on flange: IP68

2-pole terminal with mA-hood: IP65

Material Elastomer membrane, PVC-U, stainless steel 1.4571

Size

Diameter: approx. 25 mm

Length: mV version approx. 190 mm (analog signal processing)

approx.. 205 mm (digital signal processing)

Modbus version approx. 205 mm

4-20 mA version approx. 220 mm (2-pole-terminal)

approx. 190 mm (5-pole-M12)

Transport +5 … +50 °C (Sensor, electrolyte, membrane cap)

Storage

Sensor: dry and without electrolyte no limit at +5 … +40 °C

Electrolyte: in original bottle protected from sunlight at +5 … +35 °C min.

1 year or until specified EXP-Date

Membrane cap: in original packing no limit at +5 … +40 °C

(used membrane caps can not be stored)

Chemicals High Tolerance Two-Electrode System Hydrogen Peroxide Sensor For All Water Treatment

WP10

maintenance

Regularly control of the measuring signal, min. once a week

The following specifications highly depend on the water quality:

Change of the membrane cap: once a year

Change of the electrolyte: every 3 - 6 months

Chemicals High Tolerance Two-Electrode System Hydrogen Peroxide Sensor For All Water Treatment

Option 1: Retaining ring

- When operating with pressures >0.5 bar in flow cell

- Dimensions retaining ring 29 x 23.4 x 2.5 mm, slitted, PETP

- Different positions for groove selectable (on request)

Chemicals High Tolerance Two-Electrode System Hydrogen Peroxide Sensor For All Water TreatmentChemicals High Tolerance Two-Electrode System Hydrogen Peroxide Sensor For All Water Treatment

Technical Data

1. WP10 (Analog output, analog internal signal processing)

A potential-free electrical connection is necessary as the sensor electronic is not equipped with a galvanical isolation.

Chemicals High Tolerance Two-Electrode System Hydrogen Peroxide Sensor For All Water Treatment

Measuring range resolution

Output

Output resistance

Nominal slope Voltage supply Connection
WP10H-M12 0.5…200 ppm 0.1 ppm

0…-2000 mV

1 kΩ

-10 mV/ppm

±5 - ±15 VDC

10 mA

5-pole M12 plug-on flange

Function of wires:

PIN1: measuring signal PIN2: +U

PIN3: -U

PIN4: signal GND

PIN5: n. c.

WP10N-M12 5…2000 ppm 1 ppm -1 mV/ppm
WP10L-M12 0.005…2 % (20000 ppm)

0.001 %

(10 ppm)

-1000mV/%

(-0.1 mV/ppm)

WP10-20%-M12

0.05… 20%

(200000 ppm)

0.01 %

(100 ppm)

-100 mV/%

(-0.01 mV/ppm)

(Subject to technical changes!)

2. WP10 (analog output, digital signal processing)

Analog-out / digital

The power supply is galvanically isolated inside of the sensor.

The output signal is galvanically isolated too, that means potential-free.

Chemicals High Tolerance Two-Electrode System Hydrogen Peroxide Sensor For All Water Treatment

Measuring range Resolution Output Output resistance Nominal Slope Power supply Connection
WP10H-An-M12 0.5… 200.0 ppm 0.1 ppm


analog
0…-2 V (max.
-2.5 V)
1 kΩ

-10 mV/ppm 9-30 VDC
approx.
20-56 mA

5-pole M12 plug-on flange

Function of wires:

PIN1: measuring signal PIN2: +U

PIN3: power GND

PIN4: signal GND

PIN5: n. c.

WP10N-An-M12 .50… 2000 ppm 1 ppm -1 mV/ppm
WP10L-An-M12 0.005… 2 %
(20000 ppm)
0.001 %
(10 ppm)
-1000 mV/%
(-0.1 mV/ppm)
WP10-20%-An-M12

0.05… 20 %

(200000 ppm)

0.01 %

(100 ppm)

-100 mV/%

(-0.01 mV/ppm)

WP10H-Ap-M12 0.5… 200.0 ppm 0.1 ppm



analog
0…+2 V (max.
+2.5 V)
1 kΩ

+10 mV/ppm
WP10N-Ap-M12 5… 2000 ppm 1 ppm +1 mV/ppm
WP10L-Ap-M12 0.005… 2 %
(20000 ppm)
0.001 %
(10 ppm)
+1000 mV/%
(+0.1 mV/ppm)
WP10-20%-Ap-M12 0.05… 20 %
(200000 ppm)
0.01 %
(100 ppm)
+100 mV/%
(+0.01 mV/ppm)

(Subject to technical changes!)

3. WP10 (digital output, digital signal processing)

The power supply is galvanically isolated inside of the sensor.

The output signal is galvanically isolated too, that means potential-free.

Chemicals High Tolerance Two-Electrode System Hydrogen Peroxide Sensor For All Water Treatment

Measuring range Resolution

Output

Output resistance

Power supply Connection
WP10H-M0c 0.5… 200.0 ppm 0.1 ppm

Modbus RTU


There are no terminating resistors in the sensor.

9-30 VDC

approx. 20-56 mA

5-pole M12 plug-on flange

Function of wires:

PIN1: reserved

PIN2: +U

PIN3: power GND

PIN4: RS485B

PIN5: RS485A

WP10N-M0c 5… 2000 ppm 1 ppm
WP10L-M0c

0.005… 2 %

(20000 ppm)

0.001 %

(10 ppm)

WP10-20%-M0c

0.05… 20 %

(200000 ppm)

0.01 %

(100 ppm)

(Subject to technical changes!)

4. WP10 4-20 mA (analog output, analog internal signal processing)

A potential-free electrical connection is necessary as the sensor electronic is not equipped with a galvanical isolation.

4.1 Electrical connection: 2 pole terminal clamp

Chemicals High Tolerance Two-Electrode System Hydrogen Peroxide Sensor For All Water Treatment

Measuring range resolution Output Output resistance Nominal slope Voltage supply Connection
WP10MA-200 0.5… 200.0 ppm 0.1 ppm

4…20 mA

uncalibrated
0.08 mA/ppm

12…30 VDC


RL 50Ω…RL 900Ω

2-pole terminal

(2 x 1 mm²)

Recommended: Round cable

Æ 4 mm

2 x 0.34 mm²

WP10MA-2000 5… 2000 ppm 1 ppm 0.008 mA/ppm
WP10MA-2%

0.005… 2 %

(20000 ppm)

0.001 %

(10 ppm)

8 mA/%

(0.0008 mA/ppm)

WP10MA-5%

0.05… 5 %

(50000 ppm)

0.01 %

(100 ppm)

3.2 mA/%

(0.00032 mA/ppm)

WP10MA-10% 0.05… 10 %
(100000 ppm)
0.01 %
(100 ppm)
1.6 mA/%
(0.00016 mA/ppm)
WP10MA-20% 0.05… 20 %
(200000 ppm)
0.01 %
(100 ppm)
0.8 mA/%
(0.00008 mA/ppm)

(Subject to technical changes!)

4.2 Electrical connection: 5 pole M12 plug-on flange

Chemicals High Tolerance Two-Electrode System Hydrogen Peroxide Sensor For All Water Treatment

Measuring range resolution Output Output resistance Nominal slope Voltage supply Connection
WP10MA-200-M12 0.5… 200.0 ppm 0.1 ppm

4…20 mA


uncalibrated
0.08 mA/ppm

12…30 VDC


RL 50Ω…RL 900Ω

5-pole M12 plug-on flange

Function of wires: PIN1: n. c.

PIN2: +U

PIN3: -U

PIN4: n c.

PIN5: n. c.

WP10MA-2000-M12 5… 2000 ppm 1 ppm 0.008 mA/ppm
WP10MA-2%-M12

0.005… 2 %

(20000 ppm)

0.001 %

(10 ppm)

8 mA/%

(0.0008 mA/ppm)

WP10MA-5%-M12

0.05… 5 %

(50000 ppm)

0.01 %

(100 ppm)

3.2 mA/%

(0.00032 mA/ppm)

WP10MA-10%-M12 0.05… 10 %
(100000 ppm)
0.01 %
(100 ppm)
1.6 mA/%
(0.00016 mA/ppm)
WP10MA-20%-M12 0.05… 20 %
(200000 ppm)
0.01 %
(100 ppm)
0.8 mA/%
(0.00008 mA/ppm)

(Subject to technical changes!)

Spare Parts

Type Membrane cap Electrolyte Emery O-ring
All WP10H

M10.1H with G-holder Art. no. 11045.1

EWP7/W, 100 ml

Art. no. 11201

S2

Art. no. 11906

20 x 1.5 silicone

Art. no. 11803

All WP10N
All WP10L

M10.1D with G-holder Art. no. 11041.1

All WP10-20%
All WP10MA-200

M10.1H with G-holder Art. no. 11045.1

All WP10MA-2000
All WP10MA-2%

M10.1D with G-holder Art. no. 11041.1

All WP10MA-5%
All WP10MA-10%
All WP10MA-20%

(Subject to technical changes!)

Chemicals High Tolerance Two-Electrode System Hydrogen Peroxide Sensor For All Water Treatment

Chemicals High Tolerance Two-Electrode System Hydrogen Peroxide Sensor For All Water Treatment

Send your message to this supplier
Send Now

Chemicals High Tolerance Two-Electrode System Hydrogen Peroxide Sensor For All Water Treatment

Ask Latest Price
Watch Video
Brand Name :
Daruifuno
Model Number :
WP10
Certification :
CE, ISO
Place of Origin :
China
MOQ :
Negotiable
Price :
Negotiable
Contact Supplier
video
Chemicals High Tolerance Two-Electrode System Hydrogen Peroxide Sensor For All Water Treatment
Chemicals High Tolerance Two-Electrode System Hydrogen Peroxide Sensor For All Water Treatment

Suzhou Delfino Environmental Technology Co., Ltd.

Verified Supplier
5 Years
jiangsu, suzhou
Since 2015
Business Type :
Manufacturer, Exporter, Seller
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement