Electrical Instruments - Automatically Dissolve - Dissolving System - BJVP
Overview:
Temperature transmitter, local temperature gauge and liquid level switch are installed on the VI dissolving tank;
Flow meter and flow control valve are installed on the base oil pipeline;
Pressure transmitter, local pressure gauge, flow meter is installed on steam inlet pipeline;
Pressure transmitter, local pressure gauge and flow meter are installed on the Cooling water inlet pipeline;
Filter, pressure control valve and Air flow meter are installed on instrument air pipeline;
Pressure transmitter, local pressure gauge, pressure control valve is installed on Finished product VI circulation and transportation pipeline.
Type of VI:
Base oil:10~500cst; Liquid VI 7075: ~1300cst(100℃),~2800 cst(80℃) ; Liquid VI V261: ~1600cst(100℃),~3100 cst(80℃)
Parameters:
Item | Description | Parameter | Unit | Note | |
1 |
High Shear Cutter |
Motor | 20T | 132KW | Inverter Duty |
10T | 75KW | Inverter Duty | |||
380 | V | ||||
5~50 | HZ | ||||
2 |
High Shear Pump |
Flow rate | 30 | m³/h | |
Pressure | ≤0.25 | MPa.A | |||
Motor | 45 | KW | Inverter Duty | ||
380 | V | ||||
5~50 | HZ | ||||
3 | Transfer Pump | Flow rate | 30 | m³/h | |
Pressure | 1.1 | MPA | |||
Motor | 22 | KW | Inverter Duty | ||
380 | V | ||||
5~50 | HZ |