Specifications
Brand Name :
JUSHIEN
Model Number :
VGB-6-ⅠT
Certification :
CE Certification&GB/T19001-2016 idt ISO9001:2015 Standard
Place of Origin :
China
MOQ :
1
Payment Terms :
30% deposit + 70% T/T before shipping, T/T
Supply Ability :
30 sets per month
Delivery Time :
20-30 work days
Gas Inlet Pressure :
0.5-0.7MPa
Oxygen Content :
≤0.1ppm
Humidity Control :
≤0.1ppm
Vacuum Pump :
Oil-free Vacuum Pump
Operating Temperature :
≤30℃
Vacuum Pressure :
≤-0.1MPa
leakage rate :
≤ 0.001%vol /h
Description
product description
Single-sided single-unit double-station independent single-control circulation system glove box Length x width x height = 1800x 780 x 900mm Single-section standard double-station glove box, single-sided operation, standard inclined working surface.
Performance highlights

1.PLC control and touch screen operation: realize artificial intelligence to the greatest extent.

2. Fully automatic large transition chamber automatic pumping and replenishing system: just operate it simply on the touch screen.

3. Internal purification system of independent control cabinet: while reducing the space occupied by equipment, it is convenient to move and replace. It has a built-in 5Kg large-capacity organic solvent adsorption system (customized) and a large-capacity professional-grade water and oxygen purification column adsorption system, which can quickly purify the internal experimental environment of the glove box. Under standard conditions, that is, 200C constant temperature, one standard atmospheric pressure, 65% relative humidity, 99.999% inert gas source, the water-oxygen index is less than 1 ppm, and under normal circumstances, the water-oxygen index can reach less than 0.1 ppm.

basic configuration
name Serial number Configuration unit quantity Manufacturer/Brand Remark
host
want
match
Place
1 Cabinet tower 1 304 stainless steel thickness 3mm
2 Transition cabin set 1 304 stainless steel
3 Control System set 1 German SIEMENS, ABB electronic devices, etc. Imported assembly
4 Circulation system (including purification and regeneration system) set 1 BASF of Germany, UOP purification materials of the United States, Boya valves of Germany Imported assembly
5 display system set 1 SIEMENS, Germany original imported
6 Gloves pair 1 PIERCAN USA original imported
7 Pipeline interface set 1
8 Pressure gauge set 1 WIka, Germany original imported
9 Water Analyzer tower 1 Michell, UK original imported
10 Oxygen Analyzer tower 1 German OEM original imported
11 Vacuum Pump tower 1 British Edwards RV-12 original imported
12 Automatic cleaning set 1
13 Oxygen upper limit automatic sound and light alarm system set 1
14 Solvent adsorption system set 1 (Customized Project)
15 Front door opening set 1
16 Automatic air extraction and replenishment control in large transition chamber set 1 German Boya valve Imported assembly

Other configurations

name Serial number Configuration unit quantity Manufacturer/Brand Remark
That
Remain
match
Place
1 Transition bin moving slide rail set 1 Taiwan Hiwin
2 PU air pipe connector set 1 AirTac Taiwan
3 Sealing silicone components set 1 Domestic
4 Stainless steel ferrule fittings set 1 Domestic
5 Stainless steel precision steel pipe set 1 Domestic
6 Precision copper tube set 1 Domestic
7 Corrugated pipe set 1 Domestic
8 Casters set 1 Korean Fuma caster import

Technical Parameters

Technical Parameters

1. Box

1.1. Box size: length x width x height = 1800 x 780 x 900 mm.

1.2. Material: All stainless steel structure (SUS 304), thickness 3mm.

1.3. Glove opening: 220mm diameter, made of hard aluminum alloy, anti-corrosion treated.

1.4. Gloves: American PIERCAN gloves, glove diameter 8 inches, thickness 0.4 mm, butyl rubber material.

1.5. Window: The operating surface is tilted and made of 10mm safety tempered glass. The front window is affixed with a specially customized super-strong sealing ring and adopts a front door opening structure.

1.6. A certain positive and negative pressure (-12mbar to 12mbar) can be maintained during use.

1.7. The cabinet is equipped with energy-saving lamps and anti-reflective materials, which provide soft light and prevent visual fatigue.

1.8. A multi-hole power connection board (power supply: 220V±10% 50Hz±10%) is pre-installed in the box.

1.9. The box is equipped with 6 standard KF-40 interfaces for easy access to liquids, gases, signals, etc.

1.10. There are two layers of storage boards in the box, which can be adjusted up and down.

1.11. Bracket: with casters, height 914mm. The casters have the functions of leveling, moving and fixing.

1.12. Leakage rate: ≤0.05vol%/h. According to the ISO 10648-2 standard document, the indicators are clearly given:

The hourly leakage rate of the sealed box with controlled inert atmosphere is ≤5×

2. Transition cabin

Large transition cabin:

2.1. Shape: cylindrical (304 stainless steel), connected to the glove box, with automatic air extraction and air supply control.

2.2. Size: 360mm in diameter, 600mm in length, large transition cabin (right side operation), gas spring door opening method, with sliding tray in the transition cabin.

2.3. Large transition compartment tray: Stainless steel 230 mm × 595 mm, can be freely moved left and right, and the extended depth is 361 mm.

2.4. Vacuum degree: ≤-0.1MPa (large transition tank requires vacuum with display), vacuum pressure gauge uses German Wika.

Small transition cabin:

2.5. Shape: cylindrical (304 stainless steel), connected to the glove box, controlled by manual valve.

2.6. Dimensions: Ф150mm×300mm, single handle clamping method.

2.7. Vacuum degree: ≤-0.1MPa (the small transition cabin requires vacuum pumping with display), the vacuum pressure gauge is German Wika.

3. Control system

3.1. Mode: including self-diagnosis, power-off self-starting features, pressure control and adaptive functions. Automatic control, cycle control, password protection, vacuum chamber control adopt LCD display. The control unit adopts German SIEMENS PLC touch screen, and the operation menu can be selected: Chinese/English.

3.2. Pressure control: Control the pressure of the box and transition chamber at a certain set value.

3.3. Foot pedal: can control the pressure of the glove box and facilitate operation.

4. Circulation purification system

4.1. Purification capacity: water and oxygen <1ppm.

4.2. Adjustment device: Through PLC touch-type adjustment (heating, vacuuming, purification, regeneration), the whole process does not require human monitoring.

4.3. Working gas: N2 or Ar (gas circulation).

4.5. Circulation fan: imported high-speed variable frequency fan from Elektror, ​​Germany, flow rate 0-80m3/h, microprocessor controlled, pressure-tested stainless steel device.

4.6. Single purification column: German BASF deoxygenation material, American UOP high-efficiency water absorption material, including 5 kg of deoxygenation material, 60l of deoxygenation, 5 kg of dehydration material, and 2 kg of dehydration.

4.7. Purification valve: Fully automatic electro-pneumatic valve. Modular design.

4.8. Filter: Use a high-efficiency filter with a pore size of 0.3 microns that meets the HEPA standard.

5. Regeneration system

Used to purify the system for reuse and activation; regeneration requires a mixture of N2/H2 or Ar/H2, in which H2 accounts for 5-10%.

6. Display system

The control unit adopts German SIEMENS PLC touch screen, operation menu: Chinese/English.

7. Vacuum system

Automatic gas-controlled electroplating board; the vacuum pump uses the British Edwards RV12 vacuum pump. The transition chamber can be vacuumed separately and can be controlled separately at any time. (Optional item)

Technical indicators

1. Water analyzer

1.1. Range: 0-1000ppm.

1.2. Error: ±1% ppm.

1.3. Environment: -10℃ - 50℃

1.4. Display: PLC controlled display.

1.5. Especially for users such as lithium battery manufacturing and metal organic, it can be cleaned and reused, avoiding the problem of being scrapped after one contamination.

2. Oxygen analyzer

2.1. Range: 0-1000ppm.

2.2. Error: ±1% ppm.

2.3. Environment: -10℃ - 50℃

2.4. Display: PLC controlled display.

2.5. The use of ZrO2 sensors avoids the problem of short fuel cell life and inability to be exposed to the air.

3. Solvent adsorption system

3.1. The influence of agents on the purification column. The bypass system is integrated into the glove box system to effectively remove the solvent volatilized from the system. The media are mainly high-quality and efficient activated carbon and activated alumina.

3.2. Activated carbon cartridge volume and weight Kg: 14.9L/5Kg

Basic parameters

1. Net weight of glove box (Kg): 620 Kg.

2. Net dimensions of glove box (mm): length × width × height = 2580 x 1040 x 1860.

3. Total power of equipment: 0.8 Kw.

4. Internal socket provides power Kw: 2.5 Kw.

Send your message to this supplier
Send Now

Single-sided Single-unit glove box Double-station Independent VGB-6-ⅠT glove

Ask Latest Price
Brand Name :
JUSHIEN
Model Number :
VGB-6-ⅠT
Certification :
CE Certification&GB/T19001-2016 idt ISO9001:2015 Standard
Place of Origin :
China
MOQ :
1
Payment Terms :
30% deposit + 70% T/T before shipping, T/T
Contact Supplier
Single-sided Single-unit glove box Double-station Independent VGB-6-ⅠT glove
Single-sided Single-unit glove box Double-station Independent VGB-6-ⅠT glove
Single-sided Single-unit glove box Double-station Independent VGB-6-ⅠT glove
Single-sided Single-unit glove box Double-station Independent VGB-6-ⅠT glove

Hefei Jiusheng Electromechanical Technology Co., Ltd

Verified Supplier
2 Years
anhui, hefei
Since 2009
Business Type :
Manufacturer
Total Annual :
5000000-10000000
Employee Number :
50~100
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement