The Omron's CP1E series is a PLC unit which has 24 inputs, 16 relay outputs with 8K steps program and 8K words data memory. The CP1E Programmable Controller is Economical, Easy to use, and Efficient.
Complete High-speed counter functionality
Built-in analogue I/O, two inputs and one output, for NA-type CPU units
Attribute | Value |
Manufacturer Series | CP1E |
Number of Digital Inputs | 24 |
Input Type | PNP/NPN |
Number of Outputs | 16 |
Transmission distance | 5 m max. | |
Built-in RS-232C port |
No built-in RS-232C port | Interface: Conforms to EIA RS-232C. |
Communications method | Half duplex | |
synchronization | Start-stop | |
Baud rate | 1.2, 2.4, 4.8, 9.6, 19.2, 38.4, 57.6, or 115.2 kbps | |
Transmission distance | 15 m max. | |
Supported protocol | · Host Link· 1:N NT Link
· No-protocol mode · Serial PLC Links (master, slave) · Modbus-RTU Easy Master | |
Built-in RS-485 port |
No built-in RS-485 port | N30/40/60S1-type onlyInterface: Conforms to EIA RS-485. 2-wire sensors No isolation |
Communications method | Half duplex | |
synchronization | Start-stop | |
Baud rate | 1.2, 2.4, 4.8, 9.6, 19.2, 38.4, 57.6, or 115.2 kbps | |
Transmission distance | 50 m max. | |
Supported protocol | · Host Link· 1:N NT Link
· No-protocol mode · Serial PLC Links (master, slave) · Modbus-RTU Easy Master | |
Serial Option port |
Option Board cannot be mounted. | N30/40/60 and NA20-type only 1 port |
Mountable Option Boards | · One RS-232C port: CP1W-CIF01· One RS-422A/485 port (not isolated): CP1W-CIF11
· One RS-422A/485 port (isolated): CP1W-CIF12-V1 · One Ethernet port: CP1W-CIF41 | |
Communications method | Depends on Option Board. | |
synchronization | Depends on Option Board. | |
Baud rate | 1.2, 2.4, 4.8, 9.6, 19.2, 38.4, 57.6, or 115.2 kbps | |
Compatible protocols | · Host Link· 1:N NT Link
· No-protocol mode · Serial PLC Links (master, slave) · Modbus-RTU Easy Master | |
Number of tasks | 17· One cyclic execution task
· One scheduled interrupt task (always interrupt task 1) · Six input interrupt tasks (interrupt tasks 2 to 7) · Sixteen high-speed counter interrupt tasks (interrupt tasks 1 to 16) | |
Maximum subroutine number | 128 | |
Maximum jump number | 128 | |
Scheduled interrupt tasks | 1 interrupt task | |
Clock | Clock function not included.
The time of error occurrence displays 01-01-01 01:01:01 Sunday | Included.Accuracy (monthly deviation):
-4.5 min to -0.5 min at ambient temperature of 55oC, -2.0 min to +2.0 min at ambient temperature of 25oC, -2.5 min to +1.5 min at ambient temperature of 0oC |
Built-in EEPROM | Ladder programs and parameters are automatically saved to built-in EEPROM A section of the Data Memory Area can be saved to the built-in EEPROM. | |
Battery backup With CP1W-BAT01 Battery (Sold separately) |
Battery cannot be mounted. | CP1W-BAT01 can be used. Maximum battery service life: 5 years Backup TimeGuaranteed value (ambient temperature: Battery (Sold separately)Effective value (ambient temperature: 25oC): 43,000 hours (approx. 5 years) |
Input Bits | 1,600 bits (100 words): CIO 0.00 to CIO 99.15 (CIO 00 to CIO 99) | |
Output Bits | 1,600 bits (100 words): CIO 100.00 to CIO 199.15 (CIO 100 to CIO 199) | |
Serial PLC Link Words | 1,440 bits (90 words): CIO 200.00 to CIO 289.15 (words CIO 200 to CIO 289) | |
Work Area (W) | 1,600 bits (100 words): W0.00 to W99.15 (W0 to W99) | |
Holding Area (H) | 800 bits (50 words): H0.00 to H49.15 (H0 to H49)Bits in this area maintain their ON/OFF status when operating mode is changed. | |
Auxiliary Area (A) | Read-only: 7,168 bits (448 words) A0 to A447Read/write: 4,896 bits (306 words) in words A448 to A753 | |
Temporary Relay Area (TR) (TR Area) | 16 bits: TR0 to TR15 | |
Timer Area (T) | 256 timer numbers (T0 to T255 (separate from counters)) | |
Counter Area (C) | 256 counter numbers (C0 to C255 (separate from timers)) |