Exit | Rated engine power*1Kw | 120% pergr. capable. (SLD)* | 75/90 |
150% pergr. capable. (LD)* | 75 |
Rated output power, kVA*2 | 120% pergr. capable. (SLD)* | 137 |
150% pergr. capable. (LD)* | 110 |
Rated converter current*2, A | 120% pergr. capable. (SLD)* | 180 |
150% pergr. capable. (LD)* | 144 |
Overload capacity*3 | 120% pergr. capable. (SLD)* | 120% nom. current in the flow. 3 s; 110% in the current. 1 minute (at max. temp. rev. 40 ° C) |
150% pergr. capable. (LD)* | 150% nom. in the flow. 3 s; 120% in the current. 1 minute (at max. temp. rev. 50 ° C) |
Voltage*4 | 3-phase, from 380...500 V |
Nutrition | Voltage/frequency to be connected | Three-phase, 380 to 500 V, 50/60 Hz*8 |
Voltage range | 323-550 V, 50/60 Hz |
Permissible frequency fluctuation | ±5% |
Nominal input current*5And | 120% pergr. capable. (SLD)* | 180 |
150% pergr. capable. (LD)* | 144 |
Rated input power*6kilovolt-ampere | 120% pergr. capable. (SLD)* | 137 |
150% pergr. capable. (LD)* | 110 |
Ambient conditions | Ambient air temperature | -10°C... +50°С (non-condensing) (overload capacity LD, ND, HD); -10°C... +40°С (non-condensing) (SLD overload capacity) |
Permissible relative air humidity | Acc. IEC 60721-3-3, Class 3C2, Relative humidity max. 95% (non-condensing) |
Height | Maximum 1000 m above sea level |
Vibration | Maximum 0.6 g |
Other | Cooling | Fan cooling |
Degree of protection (IEC 60529)*7 | IP00 |
Standards | EN50598-2, Class IE2, a new European environmental design directive, EN50598-2, Class IES2, combined efficiency of frequency converter and motor IE3/IE4, IEC60721-3-3, Class 3C2, Environmental Class, ENISO 13849-1 PLd / Cat.3 / EN61800-5-2 SIL2 for Safety Standards |
Weight, kg | 43 |
Dimensions (WxHxD), mm | 435x550x250 |